HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 63
your HP Support Representative to analyze the fabric. WBEM EventID: 2920. WBEM
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
10213 Error 10272 Error 10273 Error 10343 Error 10351 Error 10357 Warning 10358 Warning 10361 Error 10375 Warning 10376 Warning 10377 Warning 10378 Warning One or more of the blades in the domain could not communicate. Probable Cause: Connection problem between blade and the enclosure. Recommended Action: iLO will attempt to correct communication issues. If this fails verify FW is at a supported revision and matached across the blades. Consider cycling stby power to the affected blades. WBEM EventID: 8083. WBEM ProviderName: FPL_IndicationProvider. An Arches fabric CSR read was unsuccessful because of a timeout. Probable Cause: An error occurred while reading a hardware register. Other events should detail the error. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2908. WBEM ProviderName: FPL_IndicationProvider. An Arches fabric CSR write was unsuccessful. Probable Cause: An error occurred while writing a hardware register. Other events should detail the error. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2909. WBEM ProviderName: FPL_IndicationProvider. The event data details the error that was encountered. Probable Cause: A fabric error occurred while preparing for rendezvous. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2910. WBEM ProviderName: FPL_IndicationProvider. The maximum memory supported by this system has been exceeded. Probable Cause: Too much memory has been installed in the system. Recommended Action: Remove DIMMs to get the total memory size below the amount of memory returned in the data field. WBEM EventID: 2911. WBEM ProviderName: FPL_IndicationProvider. Failed to delete a bad port while routing the fabric. Data field indicates return status. Probable Cause: Experienced an error while routing the fabric. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 4848. WBEM ProviderName: FPL_IndicationProvider. Failed to delete an edge that was found to be bad during routing. Probable Cause: Experienced an error while routing the fabric. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 4849. WBEM ProviderName: FPL_IndicationProvider. A command to the memory buffer chip failed to complete. Probable Cause: System firmware did not get a completion status from a command to a memory buffer chip. Recommended Action: Contact HP support. WBEM EventID: 2917. WBEM ProviderName: FPL_IndicationProvider. The Arches Fabric function ArfIsCsrRouteTraversable was called for a back-to-back system. This is unsupported, ArfIsCsrRouteTraversable should only be called for systems with crossbars. No data. Probable Cause: An unsupported fabric call was made. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2918. WBEM ProviderName: FPL_IndicationProvider. An invalid port number was given as an input to an Arches Fabric Traversability function. The port is expected to be an internal XBC num (8-15), but the actual port was not. Data field: (XBC number 32) | (port number 48). Probable Cause: Internal firmware error. Recommended Action: Contact your HP Support Representative to investigate the fabric and firmware vertex modules. WBEM EventID: 2919. WBEM ProviderName: FPL_IndicationProvider. Unable to read XBC port neighbor information. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2920. WBEM ProviderName: FPL_IndicationProvider. XBC port with an unexpected neighbor chip type. Data field: (expected chip type) | (actual chip type 16) | (xbcNum 32) |(portNum 48). Probable Cause: System firmware noticed a discrepancy from the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2921. WBEM ProviderName: FPL_IndicationProvider. Platform Events 63