Expected I/O host bridge is missing. Probable Cause: I/O host bridge failure. An
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
5107 5108 5118 5119 5121 5123 5124 5125 5127 5130 5131 5132 5133 5136 Error Error Warning Warning Error Warning Warning Warning Warning Warning Warning Warning Warning Warning Unexpected trap. Probable Cause: An unexpected trap has occurred. During System Firmware boot time this indicates the system has requested a trap that firmware has not registered. During OS run time it indicates the system has requested a trap that is not recognized in the OS's trap table. Recommended Action: If at FW boot time, reboot or upgrade System FW. If problem persists contact your HP representative for support. If at OS run time, verify that the OS has properly installed its trap handler, and that only valid traps are caused. Investigate what could cause the trap that is signaled by the event or why the OS has not properly installed the trap handler. If problem persists contact your HP representative for support. WBEM EventID: 263. WBEM ProviderName: FPL_IndicationProvider. CPU unknown boot error. Probable Cause: Unknown error. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 264. WBEM ProviderName: FPL_IndicationProvider. CC errors PAL failure. Probable Cause: SFW has detected a PAL Failure. Recommended Action: Reboot, update SFW if necessary, if problem persists contact your HP representative for support. WBEM EventID: 265. WBEM ProviderName: FPL_IndicationProvider. Expected MC vector unregistered. Probable Cause: Expected Machine Check Vector not registered at the time of an Expected Machine Check. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 266. WBEM ProviderName: FPL_IndicationProvider. INIT initiated. Probable Cause: Software has requested an INIT or the INIT button has been pressed. Recommended Action: No action is required. WBEM EventID: 267. WBEM ProviderName: FPL_IndicationProvider. Expected I/O host bridge is missing. Probable Cause: I/O host bridge failure. An incorrect I/O backplane is installed. Recommended Action: Contact your HP representative to check the I/O host bridge and the I/O backplane. WBEM EventID: 268. WBEM ProviderName: FPL_IndicationProvider. LBA has unexpected number of I/O slots. Probable Cause: The firmware needs to be updated. An incorrect I/O backplane is installed. Recommended Action: Contact your HP representative to check the firmware and the I/O backplane. WBEM EventID: 269. WBEM ProviderName: FPL_IndicationProvider. I/O rope width does not match expected value. Probable Cause: The firmware needs to be updated. An incorrect I/O backplane is installed. Recommended Action: Update SFW. If problem persists, contact your HP representative to check the I/O backplane. WBEM EventID: 270. WBEM ProviderName: FPL_IndicationProvider. Found unexpected I/O host bridge. Probable Cause: The firmware needs to be updated. An incorrect I/O backplane is installed. Recommended Action: Update SFW. If problem persists, contact your HP representative to check the I/O backplane. WBEM EventID: 271. WBEM ProviderName: FPL_IndicationProvider. PCI clock DLL error. Probable Cause: Failed I/O chipset. Failed I/O backplane. Recommended Action: Contact your HP representative to check the I/O chipset and backplane. WBEM EventID: 272. WBEM ProviderName: FPL_IndicationProvider. PCI hot plug controller failed. Probable Cause: Hot-plug controller failure. I/O host bridge failure. Recommended Action: Contact your HP representative to check the hot-plug controller and the I/O host bridge. WBEM EventID: 273. WBEM ProviderName: FPL_IndicationProvider. Found unknown I/O rope width. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 274. WBEM ProviderName: FPL_IndicationProvider. I/O LBA clear error failed. Probable Cause: A failed or improperly seated I/O card is present. Recommended Action: Replace or reseat the I/O card(s). WBEM EventID: 275. WBEM ProviderName: FPL_IndicationProvider. I/O host bridge inaccessible because rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended Action: Contact your HP representative to check the I/O CEC. WBEM EventID: 276. WBEM ProviderName: FPL_IndicationProvider. 22 WBEM Provider Event Tables