Probable Cause: An unknown OS IPMI driver or Manageability FW bug has occurred.

Page 53 highlights

8149 8151 8153 8154 8156 8159 8199 8200 8202 8206 8207 8212 8214 8216 8218 Warning Warning Warning Warning Error Error Warning Warning Error Error Error Warning Warning Warning Warning The PDHC has waited an abnormally long time for PDH bus access. Probable Cause: Bad connection on UGUY clock cable. Recommended Action: Check UGUY clock cable connection. WBEM EventID: 713. WBEM ProviderName: FPL_IndicationProvider. The PDHC has waited an abnormally long time to obtain the PDH semaphore. Probable Cause: System FW has control of the PDH bus semaphore, and has failed to relinquish control of it. Recommended Action: Update the System FW revision to the latest version of System FW using the Firmware Update Utility. WBEM EventID: 714. WBEM ProviderName: FPL_IndicationProvider. An error occurred while transmitting an IPMI message in the BMC2HOST direction. Probable Cause: An unknown OS IPMI driver or Manageability FW bug has occurred. Recommended Action: Update PDHC FW, MP FW, System FW and the OS IPMI driver to the latest revisions. WBEM EventID: 715. WBEM ProviderName: FPL_IndicationProvider. EFI unable to read initial debug level from the BMC. Probable Cause: SAL service to read tokens not functioning properly. Recommended Action: Reset the system. Clear SFW NVM. Upgrade system firmware. WBEM EventID: 716. WBEM ProviderName: FPL_IndicationProvider. A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 717. WBEM ProviderName: FPL_IndicationProvider. An invalid number of XBC ports were landmined in the system. Probable Cause: Hardware failure: link, crossbar chip, or cell. Recommended Action: Check for hardware failures. Reset backplane to re-initialize fabric. WBEM EventID: 1033. WBEM ProviderName: FPL_IndicationProvider. The run-time verification of a programming assumption has failed. Probable Cause: Hardware in unknown state, or programming bug found. Recommended Action: Upgrade PM firmware to latest revision. If already at current revision, replace UGUY board. WBEM EventID: 728. WBEM ProviderName: FPL_IndicationProvider. An unknown error has been detected by the PDHC firmware. Probable Cause: Hardware in unknown state, or programming bug found. Recommended Action: Upgrade PM firmware to latest revision. If already at current revision, replace UGUY board. WBEM EventID: 729. WBEM ProviderName: FPL_IndicationProvider. Data field contains data meant for firmware debug only. Probable Cause: Debug event. Recommended Action: Contact your hp support representative. WBEM EventID: 2440. WBEM ProviderName: FPL_IndicationProvider. A cabinet has been configured using an invalid cabinet number. Probable Cause: Re-configure cabinet to use a valid cabinet number. WBEM EventID: 732. WBEM ProviderName: FPL_IndicationProvider. Cells trying to join a PD are at incompatible firmware revisions. Probable Cause: The reporting cell is at a different firmware revision than the cell reported in the data field. A PD cannot be established. Please reprogram the 2 cells to the same firmware revision. WBEM EventID: 733. WBEM ProviderName: FPL_IndicationProvider. An attempt to write to a device on the PM's I2C bus has failed. Probable Cause: A hardware error has occurred. Recommended Action: Replace the UGUY board. WBEM EventID: 734. WBEM ProviderName: FPL_IndicationProvider. An attempt to read from a device on the PM's I2C bus has failed. Probable Cause: A hardware error has occurred. Recommended Action: Replace the UGUY board. WBEM EventID: 735. WBEM ProviderName: FPL_IndicationProvider. An error was encountered updating the cell info structure in ICM. Probable Cause: This should not happen. Contact engineering to diagnose the problem. WBEM EventID: 736. WBEM ProviderName: FPL_IndicationProvider. An error was encountered pointing the slave cell consoles to the diva. Probable Cause: A CPU on the slave cell could not process an interrupt in time or establish the diva console. WBEM EventID: 737. WBEM ProviderName: FPL_IndicationProvider. Platform Events 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

The PDHC has waited an abnormally long time for PDH bus access. Probable Cause:
Bad connection on UGUY clock cable. Recommended Action: Check UGUY clock
cable connection. WBEM EventID: 713. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8149
The PDHC has waited an abnormally long time to obtain the PDH semaphore.
Probable Cause: System FW has control of the PDH bus semaphore, and has failed
to relinquish control of it. Recommended Action: Update the System FW revision to
the latest version of System FW using the Firmware Update Utility. WBEM EventID:
714. WBEM ProviderName: FPL_IndicationProvider.
Warning
8151
An error occurred while transmitting an IPMI message in the BMC2HOST direction.
Probable Cause: An unknown OS IPMI driver or Manageability FW bug has occurred.
Recommended Action: Update PDHC FW, MP FW, System FW and the OS IPMI
driver to the latest revisions. WBEM EventID: 715. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8153
EFI unable to read initial debug level from the BMC. Probable Cause: SAL service to
read tokens not functioning properly. Recommended Action: Reset the system. Clear
SFW NVM. Upgrade system firmware. WBEM EventID: 716. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8154
A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC
is indicating a port failure. Recommended Action: Validate all of the cells connectivity
to the PD Check the XBC chips seating reset the system replace either cells/system
backplane. WBEM EventID: 717. WBEM ProviderName: FPL_IndicationProvider.
Error
8156
An invalid number of XBC ports were landmined in the system. Probable Cause:
Hardware failure: link, crossbar chip, or cell. Recommended Action: Check for
hardware failures. Reset backplane to re-initialize fabric. WBEM EventID: 1033.
WBEM ProviderName: FPL_IndicationProvider.
Error
8159
The run-time verification of a programming assumption has failed. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Upgrade PM firmware to latest revision. If already at current revision, replace UGUY
board. WBEM EventID: 728. WBEM ProviderName: FPL_IndicationProvider.
Warning
8199
An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Upgrade PM firmware to latest revision. If already at current revision, replace UGUY
board. WBEM EventID: 729. WBEM ProviderName: FPL_IndicationProvider.
Warning
8200
Data field contains data meant for firmware debug only. Probable Cause: Debug
event. Recommended Action: Contact your hp support representative. WBEM
EventID: 2440. WBEM ProviderName: FPL_IndicationProvider.
Error
8202
A cabinet has been configured using an invalid cabinet number. Probable Cause:
Re-configure cabinet to use a valid cabinet number. WBEM EventID: 732. WBEM
ProviderName: FPL_IndicationProvider.
Error
8206
Cells trying to join a PD are at incompatible firmware revisions. Probable Cause: The
reporting cell is at a different firmware revision than the cell reported in the data
field. A PD cannot be established. Please reprogram the 2 cells to the same firmware
revision. WBEM EventID: 733. WBEM ProviderName: FPL_IndicationProvider.
Error
8207
An attempt to write to a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board.
WBEM EventID: 734. WBEM ProviderName: FPL_IndicationProvider.
Warning
8212
An attempt to read from a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board.
WBEM EventID: 735. WBEM ProviderName: FPL_IndicationProvider.
Warning
8214
An error was encountered updating the cell info structure in ICM. Probable Cause:
This should not happen. Contact engineering to diagnose the problem. WBEM
EventID: 736. WBEM ProviderName: FPL_IndicationProvider.
Warning
8216
An error was encountered pointing the slave cell consoles to the diva. Probable Cause:
A CPU on the slave cell could not process an interrupt in time or establish the diva
console. WBEM EventID: 737. WBEM ProviderName: FPL_IndicationProvider.
Warning
8218
Platform Events