HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 91
SMI training has failed. Probable Cause: SMI Scalable Memory Interconnect link
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
12627 Warning 12863 Error 13086 Error 13093 Error 13106 Warning 13117 Warning 13118 Warning 13150 Error 13152 Error 13157 Warning 13209 Error 13211 Error Operating system is not using all available processors for the current system. Probable Cause: Operating system license doesn't allow all processors to be used, or some processors are disabled / deconfigured. Recommended Action: Verify the correct operating system license to be used; Verify if all processors are enabled. WBEM EventID: 7573. WBEM ProviderName: FPL_IndicationProvider. A Fabric Message Processor (FMP) has unexpectedly reset. The system has recovered from the problem. Probable Cause: There is a firmware problem. Recommended Action: Verify that the most recent firmware is installed on the system. WBEM EventID: 7622. WBEM ProviderName: FPL_IndicationProvider. SMI training has failed. Probable Cause: SMI (Scalable Memory Interconnect) link training has failed. Recommended Action: If seating is not an issue, replace the EMB (Extended Memory Buffer), followed by the CPU. If not resolved, call support. WBEM EventID: 8039. WBEM ProviderName: FPL_IndicationProvider. DIMM at field location has been previously deallocated and remains deallocated. Probable Cause: A DIMM has been deallocated due to failure during memory init sequence. The most. Probable Cause is a faulty DIMM. Other possible causes could be due to SMI failure, DDR3 training failure, or bad SMB (Scalable Memory Buffer) initialization. Recommended Action: The first action will be to replace the DIMM. If that does not solve the issue, replace CPU. If problem still continues to exist, replace the system board. WBEM EventID: 8040. WBEM ProviderName: FPL_IndicationProvider. Multi-blade conjoined rendezvous has failed. Probable Cause: Event occurs when rendezous among all known logical processors does not occur. All processors need to checkin with the monarch processor. Recommended Action: Check if the SBL (Scalable Blade Link) connector is damaged. Replace if damaged. If not, check, then replace processor. If problem persists, contact Support. WBEM EventID: 8044. WBEM ProviderName: FPL_IndicationProvider. Expected blades failed to rendezvous at memory checkpoint. Probable Cause: Processors failed to rendezvous at memory checkpoint. Recommended Action: Reboot. If problem persists, replace SBL (Scalable Blade Link), if applicable. If this does not resolve, then replace processor, then contact Support. WBEM EventID: 8046. WBEM ProviderName: FPL_IndicationProvider. Expected blades failed to rendezvous at memory test checkpoint. Probable Cause: Expected processors failed to rendezvous at memory test checkpoint. Recommended Action: Reboot. If problem persists, replace processor specified by physical location, then contact Support. WBEM EventID: 8047. WBEM ProviderName: FPL_IndicationProvider. System topology (CPUs and IOHs) discovered is not a supported topology. Probable Cause: A QPI hardware error may have occurred. Recommended Action: Try rebooting the server. If problem persists contact support. WBEM EventID: 8066. WBEM ProviderName: FPL_IndicationProvider. Could not find default QPI data. Probable Cause: A hardware error may have occurred. Recommended Action: Try rebooting the server. If problem persists contact support. WBEM EventID: 8067. WBEM ProviderName: FPL_IndicationProvider. Detected a CPU QPI link's operation is degraded. Probable Cause: QPI link hardware has been detected operating with degraded performance. Recommended Action: Reboot. If problem persists contact support. WBEM EventID: 8068. WBEM ProviderName: FPL_IndicationProvider. Nested Interrupt occurred. Probable Cause: Firmware issue. Recommended Action: Contact your HP support representative. WBEM EventID: 8079. WBEM ProviderName: FPL_IndicationProvider. The CPUs across the system or SBL domain must all be the same type. Probable Cause: The part number of CPUs in the system/SBL domain are not the same. Recommended Action: The CPUs in the system or SBL domain must be the same part number. Check the FRU data using the DF command at the CM> menu. The S/SPEC should match and the core stepping should have a delta no greater than 1 across all CPUs. WBEM EventID: 8080. WBEM ProviderName: FPL_IndicationProvider. Platform Events 91