HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 20

SAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted.

Page 20 highlights

5057 5058 5059 5060 5063 5064 5065 5067 5069 5070 5073 5076 5077 5078 5079 5080 Warning Warning Warning Error Warning Error Error Warning Error Error Error Error Error Error Warning Warning Slave is incompatible with monarch. Probable Cause: Incompatible processors. Recommended Action: Replace processors. WBEM EventID: 230. WBEM ProviderName: FPL_IndicationProvider. Interrupt clear failure. Probable Cause: Interrupt clear failed. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 231. WBEM ProviderName: FPL_IndicationProvider. System Event Log (SEL) access failed. Probable Cause: An IPMI event has failed. Recommended Action: Reset the BMC and reboot. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 232. WBEM ProviderName: FPL_IndicationProvider. Trap taken. Probable Cause: This will follow other events indicating some type of IVT error. Recommended Action: This event is for debugging the address, other events will determine the user action. WBEM EventID: 233. WBEM ProviderName: FPL_IndicationProvider. LDB State bad on entry. Probable Cause: No action is required. WBEM EventID: 234. WBEM ProviderName: FPL_IndicationProvider. Interrupt with ic bit clear. Probable Cause: Interrupt context was lost because the ic bit was cleared. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 235. WBEM ProviderName: FPL_IndicationProvider. Min-state registration failure. Probable Cause: Registering of the processor min state save area with PAL has failed. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 236. WBEM ProviderName: FPL_IndicationProvider. Boot monarch timed out. Probable Cause: The monarch has timed out. Recommended Action: No action is required. Replace CPU if problem persists, system will reboot after this event. WBEM EventID: 238. WBEM ProviderName: FPL_IndicationProvider. PAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 239. WBEM ProviderName: FPL_IndicationProvider. SAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 240. WBEM ProviderName: FPL_IndicationProvider. NVRAM test fail. Probable Cause: NVM is corrupt or bad. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 241. WBEM ProviderName: FPL_IndicationProvider. Interrupt vector out of range. Probable Cause: An internal error has occurred. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 242. WBEM ProviderName: FPL_IndicationProvider. Pal proc error getting pal copy info. Probable Cause: PAL_COPY_PAL_INFO call returned a failure. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 243. WBEM ProviderName: FPL_IndicationProvider. Pal proc error copying pal to memory. Probable Cause: There has been an error copying PAL to memory. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 244. WBEM ProviderName: FPL_IndicationProvider. Boot pal proc failure. Probable Cause: Internal PAL Error. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 245. WBEM ProviderName: FPL_IndicationProvider. Console device failure. Probable Cause: A console device has failed. Recommended Action: Reset console device/system. WBEM EventID: 246. WBEM ProviderName: FPL_IndicationProvider. 20 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Slave is incompatible with monarch. Probable Cause: Incompatible processors.
Recommended Action: Replace processors. WBEM EventID: 230. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5057
Interrupt clear failure. Probable Cause: Interrupt clear failed. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 231. WBEM ProviderName: FPL_IndicationProvider.
Warning
5058
System Event Log (SEL) access failed. Probable Cause: An IPMI event has failed.
Recommended Action: Reset the BMC and reboot. If problem persists, contact HP
support to troubleshoot the problem. WBEM EventID: 232. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5059
Trap taken. Probable Cause: This will follow other events indicating some type of
IVT error. Recommended Action: This event is for debugging the address, other
events will determine the user action. WBEM EventID: 233. WBEM ProviderName:
FPL_IndicationProvider.
Error
5060
LDB State bad on entry. Probable Cause: No action is required. WBEM EventID: 234.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5063
Interrupt with ic bit clear. Probable Cause: Interrupt context was lost because the ic
bit was cleared. Recommended Action: Reboot, if problem persists contact your HP
representative for support. WBEM EventID: 235. WBEM ProviderName:
FPL_IndicationProvider.
Error
5064
Min-state registration failure. Probable Cause: Registering of the processor min state
save area with PAL has failed. Recommended Action: Reboot, if problem persists
contact your HP representative for support. WBEM EventID: 236. WBEM
ProviderName: FPL_IndicationProvider.
Error
5065
Boot monarch timed out. Probable Cause: The monarch has timed out. Recommended
Action: No action is required. Replace CPU if problem persists, system will reboot
after this event. WBEM EventID: 238. WBEM ProviderName: FPL_IndicationProvider.
Warning
5067
PAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 239. WBEM ProviderName: FPL_IndicationProvider.
Error
5069
SAL_B not in FIT table. Probable Cause: Internal Error or ROM is corrupted.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 240. WBEM ProviderName: FPL_IndicationProvider.
Error
5070
NVRAM test fail. Probable Cause: NVM is corrupt or bad. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 241. WBEM ProviderName: FPL_IndicationProvider.
Error
5073
Interrupt vector out of range. Probable Cause: An internal error has occurred.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 242. WBEM ProviderName: FPL_IndicationProvider.
Error
5076
Pal proc error getting pal copy info. Probable Cause: PAL_COPY_PAL_INFO call
returned a failure. Recommended Action: Reboot, if problem persists contact your
HP representative for support. WBEM EventID: 243. WBEM ProviderName:
FPL_IndicationProvider.
Error
5077
Pal proc error copying pal to memory. Probable Cause: There has been an error
copying PAL to memory. Recommended Action: Reboot, if problem persists contact
your HP representative for support. WBEM EventID: 244. WBEM ProviderName:
FPL_IndicationProvider.
Error
5078
Boot pal proc failure. Probable Cause: Internal PAL Error. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 245. WBEM ProviderName: FPL_IndicationProvider.
Warning
5079
Console device failure. Probable Cause: A console device has failed. Recommended
Action: Reset console device/system. WBEM EventID: 246. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5080
20