HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 17
EventID: 140. WBEM ProviderName: SEL02_IndicationProvider.
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
754 Error Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 102. WBEM ProviderName: SEL02_IndicationProvider. 755 Warning One of the temperature sensors crossed its upper non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: You should quit applications and shutdown the system.Find cause of temperature anomaly and fix it. WBEM EventID: 107. WBEM ProviderName: SEL02_IndicationProvider. 755 Warning One of the temperature sensors crossed its upper non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: You should quit applications and shutdown the system.Find cause of temperature anomaly and fix it. WBEM EventID: 107. WBEM ProviderName: SEL02_IndicationProvider. 756 Error A temperature inside the server went far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 108. WBEM ProviderName: SEL02_IndicationProvider. 756 Error A temperature inside the server went far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 108. WBEM ProviderName: SEL02_IndicationProvider. 757 Warning The AC voltage to the power supply was lost or is out of range. Probable Cause: The AC voltage was lost, or is the wrong range for the system. Recommended Action: Verify the power supply is plugged in to the proper voltage for the system. WBEM EventID: 140. WBEM ProviderName: SEL02_IndicationProvider. 757 Warning The AC voltage to the power supply was lost or is out of range. Probable Cause: The AC voltage was lost, or is the wrong range for the system. Recommended Action: Verify the power supply is plugged in to the proper voltage for the system. WBEM EventID: 140. WBEM ProviderName: SEL02_IndicationProvider. 758 Warning The power supply AC voltage is out of range. Probable Cause: The AC voltage is connected to the power supply, but it is not the voltage range required for the system. Recommended Action: Connect the power supply to the proper voltage range. WBEM EventID: 141. WBEM ProviderName: SEL02_IndicationProvider. Platform Events 17