HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 64

Error reading Skyline ALREC_ALB_ID CSR. Data field: Skyline port | Cell number

Page 64 highlights

10379 Warning 10380 Warning 10381 Warning 10382 Warning 10384 Warning 10385 Warning 10386 Warning 10387 Warning 10388 Warning 10389 Warning 10390 Warning An XBC port was found to have an unexpected neighbor ID. Data field: (expected NID) | (actual NID 16) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware found a discrepancy in the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2922. WBEM ProviderName: FPL_IndicationProvider. An XBC was found to have an unexpected neighbor port connection. Data field: (expected port) | (actual port 16) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware found a discrepancy in the expected topology of the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2923. WBEM ProviderName: FPL_IndicationProvider. The expected data was not found in the Arches Fabric expected edge list. Data field is unused. Probable Cause: Internal system firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2924. WBEM ProviderName: FPL_IndicationProvider. An XBC port has an unexpected neighbor chip type. Data field: neighbor type found. Probable Cause: System firmware found an unexpected chip in the system. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2925. WBEM ProviderName: FPL_IndicationProvider. A previously good XBC-XBC link was found to be down. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A link that was previously healthy was found to be down. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2926. WBEM ProviderName: FPL_IndicationProvider. An XBC port was found to have a Fatal Error during traversability test. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A link was found to have fatal errors, possible bad link/connection. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2927. WBEM ProviderName: FPL_IndicationProvider. Unable to read the local cell's LINK_SEL_FABRIC CSR. Data field: unused. Probable Cause: System firmware was unable to read a hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2928. WBEM ProviderName: FPL_IndicationProvider. Unable to read the XBC route table. Data field: (route index) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2929. WBEM ProviderName: FPL_IndicationProvider. An XBC link was found to be not connected while testing CSR traffic traversability. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A previously healthy link was found to be down. Possible bad cable/connection. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2930. WBEM ProviderName: FPL_IndicationProvider. Error reading Skyline ALREC_ALB_ID CSR. Data field: (Skyline port) | (Cell number 56). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2931. WBEM ProviderName: FPL_IndicationProvider. A circular route was found while testing XBC CSR traffic traversability. Data field: (target XBC 32) | (cellNum 56). Probable Cause: Internal firmware error, fabric was routed incorrectly. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2932. WBEM ProviderName: FPL_IndicationProvider. 64 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

An XBC port was found to have an unexpected neighbor ID. Data field: (expected
NID) | (actual NID 16) | (xbcNum 32) | (portNum 48). Probable Cause: System
firmware found a discrepancy in the expected topology of the system. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2922. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10379
An XBC was found to have an unexpected neighbor port connection. Data field:
(expected port) | (actual port 16) | (xbcNum 32) | (portNum 48). Probable Cause:
System firmware found a discrepancy in the expected topology of the system.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2923. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10380
The expected data was not found in the Arches Fabric expected edge list. Data field
is unused. Probable Cause: Internal system firmware error or data corruption.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2924. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10381
An XBC port has an unexpected neighbor chip type. Data field: neighbor type found.
Probable Cause: System firmware found an unexpected chip in the system.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2925. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10382
A previously good XBC-XBC link was found to be down. Data field: (xbcNum 32) |
(portNum 48). Probable Cause: A link that was previously healthy was found to be
down. Recommended Action: Capture IPMI event logs, look for additional errors.
Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2926.
WBEM ProviderName: FPL_IndicationProvider.
Warning
10384
An XBC port was found to have a Fatal Error during traversability test. Data field:
(xbcNum 32) | (portNum 48). Probable Cause: A link was found to have fatal errors,
possible bad link/connection. Recommended Action: Capture IPMI event logs, look
for additional errors. Contact your HP Support Representative to analyze the fabric.
WBEM EventID: 2927. WBEM ProviderName: FPL_IndicationProvider.
Warning
10385
Unable to read the local cell's LINK_SEL_FABRIC CSR. Data field: unused. Probable
Cause: System firmware was unable to read a hardware register. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2928. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10386
Unable to read the XBC route table. Data field: (route index) | (xbcNum 32) |
(portNum 48). Probable Cause: System firmware was unable to read a fabric hardware
register. Recommended Action: Capture IPMI event logs, look for additional errors.
Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2929.
WBEM ProviderName: FPL_IndicationProvider.
Warning
10387
An XBC link was found to be not connected while testing CSR traffic traversability.
Data field: (xbcNum 32) | (portNum 48). Probable Cause: A previously healthy link
was found to be down. Possible bad cable/connection. Recommended Action: Capture
IPMI event logs, look for additional errors. Contact your HP Support Representative
to analyze the fabric. WBEM EventID: 2930. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10388
Error reading Skyline ALREC_ALB_ID CSR. Data field: (Skyline port) | (Cell number
56). Probable Cause: System firmware was unable to read a fabric hardware register.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2931. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10389
A circular route was found while testing XBC CSR traffic traversability. Data field:
(target XBC 32) | (cellNum 56). Probable Cause: Internal firmware error, fabric was
routed incorrectly. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2932. WBEM ProviderName: FPL_IndicationProvider.
Warning
10390
64
WBEM Provider Event Tables