HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 39
Cannot read a system ID. Probable Cause: BMC failure. Recommended Action
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
5750 5751 5752 5753 5755 5756 5757 5758 5760 5762 5763 5764 5766 Warning Warning Warning Warning Error Error Error Error Warning Error Error Error Error Cannot get system ID status from BMC. Probable Cause: The communication with the system ID is lost. Recommended Action: Reset the BMC using the 'rb' command from the MP. If this doesn't work (or no MP available), unplug power from the system for 10 seconds and try rebooting the system. WBEM EventID: 495. WBEM ProviderName: FPL_IndicationProvider. Cannot read a system ID. Probable Cause: BMC failure. Recommended Action: Unplug power from the system for 10 seconds and try rebooting the system. WBEM EventID: 496. WBEM ProviderName: FPL_IndicationProvider. Failed to write new system ID. BMC reported an error. Probable Cause: Inaccessible/corrupted FRU EEPROM on system board and/or I/O backplane. Recommended Action: Check content of FRU EEPROM of the system board and secondary location using ifru. If FRU EEPROM content can be accessed on both board flash BMC firmware. If content cannot be accessed on system board replace system board. If content cannot be accessed from the secondary location, replace the secondary location FRU. If it cannot be done or doesn't solve the issue replace system board. WBEM EventID: 497. WBEM ProviderName: FPL_IndicationProvider. The system ID(s) currently in the system is invalid. Probable Cause: The system ID(s) is invalid and the user did not elect to fix the problem. Recommended Action: Reboot the system and follow the prompts to fix the issue. WBEM EventID: 498. WBEM ProviderName: FPL_IndicationProvider. EFI unable to find the SAL services for installing interrupt handlers. Probable Cause: Mismatch between EFI and SAL. Recommended Action: Upgrade system firmware. WBEM EventID: 499. WBEM ProviderName: FPL_IndicationProvider. EFI unable to find the SAL service to install run-time interrupt handlers. Probable Cause: Mismatch between EFI and SAL. Recommended Action: Upgrade system firmware. WBEM EventID: 500. WBEM ProviderName: FPL_IndicationProvider. EFI unable to find the SAL services for installing interrupt handlers. Probable Cause: Mismatch between EFI and SAL portions of the system firmware. Recommended Action: Reboot, if problem persists, contact your HP representative for support. WBEM EventID: 501. WBEM ProviderName: FPL_IndicationProvider. EFI unable to find the SAL service to install boot-time interrupt handlers. Probable Cause: Mismatch between EFI and SAL. Recommended Action: Reboot or upgrade system firmware. If problem persists contact your HP representative for support. WBEM EventID: 502. WBEM ProviderName: FPL_IndicationProvider. Too many parameters were passed to the utilities system. Probable Cause: This is a firmware error. Contact FW engineering. WBEM EventID: 2463. WBEM ProviderName: FPL_IndicationProvider. A crossbar port is unexpectedly not present. Probable Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 504. WBEM ProviderName: FPL_IndicationProvider. A crossbar port unexpectedly has its HW_LINK_OK bit not set. Probable Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 505. WBEM ProviderName: FPL_IndicationProvider. A connected port was found to be in FE. Probable Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 506. WBEM ProviderName: FPL_IndicationProvider. There was an error while initializing the Concorde-Xbc interface. Probable Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 507. WBEM ProviderName: FPL_IndicationProvider. Platform Events 39