HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 52

to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM

Page 52 highlights

8132 8133 8134 8135 8136 8137 8138 8139 8140 8141 8143 8147 Warning Warning Warning Warning Warning Error Warning Warning Error Error Warning Error An unknown error has been detected by the PDHC firmware. Probable Cause: Hardware in unknown state, or programming bug found. Recommended Action:. Recommended Action: Upgrade PDHC firmware to latest revision. If already at current revision, contact HP support personnel to troubleshoot the problem. WBEM EventID: 627. WBEM ProviderName: FPL_IndicationProvider. An attempt to write to a device on the PDHCs I2C bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM EventID: 628. WBEM ProviderName: FPL_IndicationProvider. An attempt to read from a device on the PDHC's I2C bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM EventID: 629. WBEM ProviderName: FPL_IndicationProvider. An attempt to write to a device on the PDHC's SM bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM EventID: 630. WBEM ProviderName: FPL_IndicationProvider. An attempt to read from a device on the PDHC's SM bus has failed. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board, and PDH Daughtercard. WBEM EventID: 631. WBEM ProviderName: FPL_IndicationProvider. Cell boot has been disabled due to a failure setting the frequency registers. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 632. WBEM ProviderName: FPL_IndicationProvider. An error has occurred while updating System FW. Probable Cause: Obsolete version of FWUU. Recommended Action: If you are not using the latest revision of FWUU, obtain and use the latest version of FWUU to retry the update. WBEM EventID: 633. WBEM ProviderName: FPL_IndicationProvider. The PDHC firmware was reset for some unknown reason. Probable Cause: A PDHC watchdog timer timeout has occurred because the PDHC was stuck in some unknown state. Recommended Action: Upgrade PDHC firmware to the latest revision. If the error continues, contact HP support personnel to troubleshoot the PDH Daughtercard and/or Cell Board. WBEM EventID: 634. WBEM ProviderName: FPL_IndicationProvider. Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable Cause: A hardware fault exists in the communication path to a CPU module's thermal sensor, or in the thermal sensor itself. Recommended Action: Contact HP support personnel to troubleshoot the Cell Board, the PDH Daughtercard, and/or the offending CPU module. WBEM EventID: 635. WBEM ProviderName: FPL_IndicationProvider. A CPU module has reported overtemp, so will be powered off in 1 minute. Probable Cause: A hardware fault has caused the CPU module to heat up beyond the programmed temperature threshold. Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 636. WBEM ProviderName: FPL_IndicationProvider. An error occurred while updating the PDHC firmware. Probable Cause: Other error indicated by Firmware Update. Recommended Action: Exit from Firmware Update, reset the MP using the XD command, then attempt to update PDHC firmware again. If repeated attempts to update the PDHC firmware fail, contact HP support personnel to troubleshoot the problem. WBEM EventID: 637. WBEM ProviderName: FPL_IndicationProvider. Boot is disabled because the cell type does not match the System FW ROM type. Probable Cause: The cell's installed CPU modules do not all have the same type, frequency and partition compatibility, so the Cell type cannot be accurately determined. Recommended Action: Contact HP support personnel to troubleshoot the mismatched CPU module. WBEM EventID: 712. WBEM ProviderName: FPL_IndicationProvider. 52 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:.
Recommended Action: Upgrade PDHC firmware to latest revision. If already at
current revision, contact HP support personnel to troubleshoot the problem. WBEM
EventID: 627. WBEM ProviderName: FPL_IndicationProvider.
Warning
8132
An attempt to write to a device on the PDHCs I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 628. WBEM ProviderName: FPL_IndicationProvider.
Warning
8133
An attempt to read from a device on the PDHC's I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 629. WBEM ProviderName: FPL_IndicationProvider.
Warning
8134
An attempt to write to a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 630. WBEM ProviderName: FPL_IndicationProvider.
Warning
8135
An attempt to read from a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and PDH Daughtercard. WBEM
EventID: 631. WBEM ProviderName: FPL_IndicationProvider.
Warning
8136
Cell boot has been disabled due to a failure setting the frequency registers. Probable
Cause: A hardware fault has occurred. Recommended Action: Contact HP Support
personnel to troubleshoot the problem. WBEM EventID: 632. WBEM ProviderName:
FPL_IndicationProvider.
Error
8137
An error has occurred while updating System FW. Probable Cause: Obsolete version
of FWUU. Recommended Action: If you are not using the latest revision of FWUU,
obtain and use the latest version of FWUU to retry the update. WBEM EventID: 633.
WBEM ProviderName: FPL_IndicationProvider.
Warning
8138
The PDHC firmware was reset for some unknown reason. Probable Cause: A PDHC
watchdog timer timeout has occurred because the PDHC was stuck in some unknown
state. Recommended Action: Upgrade PDHC firmware to the latest revision. If the
error continues, contact HP support personnel to troubleshoot the PDH Daughtercard
and/or Cell Board. WBEM EventID: 634. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8139
Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable
Cause: A hardware fault exists in the communication path to a CPU module's thermal
sensor, or in the thermal sensor itself. Recommended Action: Contact HP support
personnel to troubleshoot the Cell Board, the PDH Daughtercard, and/or the offending
CPU module. WBEM EventID: 635. WBEM ProviderName: FPL_IndicationProvider.
Error
8140
A CPU module has reported overtemp, so will be powered off in 1 minute. Probable
Cause: A hardware fault has caused the CPU module to heat up beyond the
programmed temperature threshold. Recommended Action: Contact HP support
personnel to troubleshoot the problem. WBEM EventID: 636. WBEM ProviderName:
FPL_IndicationProvider.
Error
8141
An error occurred while updating the PDHC firmware. Probable Cause: Other error
indicated by Firmware Update. Recommended Action: Exit from Firmware Update,
reset the MP using the XD command, then attempt to update PDHC firmware again.
If repeated attempts to update the PDHC firmware fail, contact HP support personnel
to troubleshoot the problem. WBEM EventID: 637. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8143
Boot is disabled because the cell type does not match the System FW ROM type.
Probable Cause: The cell's installed CPU modules do not all have the same type,
frequency and partition compatibility, so the Cell type cannot be accurately
determined. Recommended Action: Contact HP support personnel to troubleshoot
the mismatched CPU module. WBEM EventID: 712. WBEM ProviderName:
FPL_IndicationProvider.
Error
8147
52