HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 16
WBEM ProviderName: SEL02_IndicationProvider.
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
751 Warning PCI parity error detected. Probable Cause: An I/O device (or host bridge) detected a bus parity error, OR An I/O device (or host bridge) mastered a bus transaction and received a parity error response from the target. Recommended Action: For an I/O bus parity error, consult the error logs for additional information. Determine and replace the failed I/O device. For an I/O host bridge failure, contact your HP representative to check the I/O host bridge. WBEM EventID: 171. WBEM ProviderName: SEL02_IndicationProvider. 752 Warning Temperature sensor crossed lower non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. You should quit applications and power down the server to protect its hardware from damage. This event may indicate one of the following conditions: A failed fan, blocked air vents or poor ventilation around the server, open server chassis cover, or missing drive slot covers, high temperature in the room where the server resides, an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: You should quit applications and shutdown the system. Find cause of temperature anomaly and fix it. WBEM EventID: 100. WBEM ProviderName: SEL02_IndicationProvider. 752 Warning Temperature sensor crossed lower non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. You should quit applications and power down the server to protect its hardware from damage. This event may indicate one of the following conditions: A failed fan, blocked air vents or poor ventilation around the server, open server chassis cover, or missing drive slot covers, high temperature in the room where the server resides, an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: You should quit applications and shutdown the system. Find cause of temperature anomaly and fix it. WBEM EventID: 100. WBEM ProviderName: SEL02_IndicationProvider. 753 Error A temperature inside the server went far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 101. WBEM ProviderName: SEL02_IndicationProvider. 753 Error A temperature inside the server went far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 101. WBEM ProviderName: SEL02_IndicationProvider. 754 Error Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 102. WBEM ProviderName: SEL02_IndicationProvider. 16 WBEM Provider Event Tables