Second CPU in Pair has been disabled. Probable Cause: The second CPU in the Dual

Page 58 highlights

8941 8942 8954 8979 8981 8982 9000 9019 9043 9045 9379 9380 9382 9383 Error Error Warning Warning Warning Warning Warning Error Warning Warning Warning Warning Error Warning Cell has been disabled by PDHC FW because the CPU modules are not compatible. Probable Cause: The FRUID data stored in a CPU Module's Scratch/FRUID EEPROM is incorrectly programmed. Recommended Action: Reprogram the FRUID data (manufacturing only) or contact HP support personnel to troubleshoot the CPU module on the Cell. WBEM EventID: 867. WBEM ProviderName: FPL_IndicationProvider. Cell has been disabled because of invalid data in a CPU module Scratch EEPROM. Probable Cause: The CPU module is not an HP CPU module, or the FRUID data for this CPU module has not been programmed. Recommended Action: Contact HP support personnel to troubleshoot the CPU module. WBEM EventID: 868. WBEM ProviderName: FPL_IndicationProvider. The Cell Battery voltage level low warning. Probable Cause: The Cell Battery is low. Recommended Action: It needed to be replaced. WBEM EventID: 869. WBEM ProviderName: FPL_IndicationProvider. The CPU is performance or functionally restricted. Probable Cause: A CPU is broken. Replace it. WBEM EventID: 885. WBEM ProviderName: FPL_IndicationProvider. The RTC was found to be invalid and has been cleared. Probable Cause: The RTC was invalid. Recommended Action: No action is required. The problem has been corrected by SFW. WBEM EventID: 886. WBEM ProviderName: FPL_IndicationProvider. Status indicates that the Late Self Tests did not actually run. Probable Cause: This could be caused by an incompatibity problem between PAL and the CPUs. Check that PAL supports all the CPUs installed on the system. WBEM EventID: 887. WBEM ProviderName: FPL_IndicationProvider. DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing DIMM. Recommended Action: Replace the DIMM flagged by SFW. WBEM EventID: 890. WBEM ProviderName: FPL_IndicationProvider. System Clocks are not valid. Probable Cause: The Cell board has a problem. Either the Real Time Clock is not working properly or the system is not being clocked at the value it thinks it is. WBEM EventID: 891. WBEM ProviderName: FPL_IndicationProvider. A reset for reconfiguration will be performed soon on the cell. Probable Cause: An error during cell initialization occurred and the cell will not be able to join the partition. Look for other errors in the event log that articulate the exact problem. WBEM EventID: 900. WBEM ProviderName: FPL_IndicationProvider. The Partition Profile specifies the wrong architecture type. Probable Cause: This is caused by the wrong type of complex profile being loaded. System firmware will default a new partition profile and continue on. WBEM EventID: 901. WBEM ProviderName: FPL_IndicationProvider. CPU Dual Core Initialization Failed. Probable Cause: MX2 initialization failed. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 918. WBEM ProviderName: FPL_IndicationProvider. Second CPU in Pair has been disabled. Probable Cause: The second CPU in the Dual Core has been deconfigured as a result of the first core being deconfigured. Recommended Action: Investigate the cause of the first core being deconfigured. WBEM EventID: 919. WBEM ProviderName: FPL_IndicationProvider. Virtualzing Dual Core Registers Failed. Probable Cause: FW failed to virtualize the mx2 interposer. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 920. WBEM ProviderName: FPL_IndicationProvider. Virtualizing Dual Core Interposer has failed. Probable Cause: Virtualizing the Dual Core Interposer has failed. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 921. WBEM ProviderName: FPL_IndicationProvider. 58 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Cell has been disabled by PDHC FW because the CPU modules are not compatible.
Probable Cause: The FRUID data stored in a CPU Module's Scratch/FRUID EEPROM
is incorrectly programmed. Recommended Action: Reprogram the FRUID data
(manufacturing only) or contact HP support personnel to troubleshoot the CPU
module on the Cell. WBEM EventID: 867. WBEM ProviderName:
FPL_IndicationProvider.
Error
8941
Cell has been disabled because of invalid data in a CPU module Scratch EEPROM.
Probable Cause: The CPU module is not an HP CPU module, or the FRUID data for
this CPU module has not been programmed. Recommended Action: Contact HP
support personnel to troubleshoot the CPU module. WBEM EventID: 868. WBEM
ProviderName: FPL_IndicationProvider.
Error
8942
The Cell Battery voltage level low warning. Probable Cause: The Cell Battery is low.
Recommended Action: It needed to be replaced. WBEM EventID: 869. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8954
The CPU is performance or functionally restricted. Probable Cause: A CPU is broken.
Replace it. WBEM EventID: 885. WBEM ProviderName: FPL_IndicationProvider.
Warning
8979
The RTC was found to be invalid and has been cleared. Probable Cause: The RTC
was invalid. Recommended Action: No action is required. The problem has been
corrected by SFW. WBEM EventID: 886. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8981
Status indicates that the Late Self Tests did not actually run. Probable Cause: This
could be caused by an incompatibity problem between PAL and the CPUs. Check
that PAL supports all the CPUs installed on the system. WBEM EventID: 887. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8982
DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing
DIMM. Recommended Action: Replace the DIMM flagged by SFW. WBEM EventID:
890. WBEM ProviderName: FPL_IndicationProvider.
Warning
9000
System Clocks are not valid. Probable Cause: The Cell board has a problem. Either
the Real Time Clock is not working properly or the system is not being clocked at
the value it thinks it is. WBEM EventID: 891. WBEM ProviderName:
FPL_IndicationProvider.
Error
9019
A reset for reconfiguration will be performed soon on the cell. Probable Cause: An
error during cell initialization occurred and the cell will not be able to join the
partition. Look for other errors in the event log that articulate the exact problem.
WBEM EventID: 900. WBEM ProviderName: FPL_IndicationProvider.
Warning
9043
The Partition Profile specifies the wrong architecture type. Probable Cause: This is
caused by the wrong type of complex profile being loaded. System firmware will
default a new partition profile and continue on. WBEM EventID: 901. WBEM
ProviderName: FPL_IndicationProvider.
Warning
9045
CPU Dual Core Initialization Failed. Probable Cause: MX2 initialization failed.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 918. WBEM ProviderName: FPL_IndicationProvider.
Warning
9379
Second CPU in Pair has been disabled. Probable Cause: The second CPU in the Dual
Core has been deconfigured as a result of the first core being deconfigured.
Recommended Action: Investigate the cause of the first core being deconfigured.
WBEM EventID: 919. WBEM ProviderName: FPL_IndicationProvider.
Warning
9380
Virtualzing Dual Core Registers Failed. Probable Cause: FW failed to virtualize the
mx2 interposer. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 920. WBEM ProviderName:
FPL_IndicationProvider.
Error
9382
Virtualizing Dual Core Interposer has failed. Probable Cause: Virtualizing the Dual
Core Interposer has failed. Recommended Action: Reboot. If problem persists contact
your HP representative for support. WBEM EventID: 921. WBEM ProviderName:
FPL_IndicationProvider.