HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 78
IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
11538 Warning 11565 Error 11566 Error 11567 Error 11568 Error 11569 Error 11575 Error 11576 Error 11577 Error 11578 Error 11579 Error 11580 Warning 11581 Warning Processors have been reconfigured due to installation of a new processor type, or SFW revision change. Probable Cause: Either all CPUs were slated for deconfiguration, or NVM has been cleared, or a new CPU type has been installed. Recommended Action: No action is required. WBEM EventID: 5262. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 1.5V power fault. Probable Cause: One of the 1.5v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 7663. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 3.3V power fault. Probable Cause: One of the 3.3v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6825. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 5.0V power fault. Probable Cause: One of the 5.0v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6826. WBEM ProviderName: FPL_IndicationProvider. IO Backplane -12V power fault. Probable Cause: One of the -12v VRM's is reporting a fault, one failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6827. WBEM ProviderName: FPL_IndicationProvider. IO Backplane +12V power fault. Probable Cause: One of the +12v VRM's is reporting a fault. One failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board. Faulted VRM is given by PS command. WBEM EventID: 6828. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 1.5V temperature fault. Probable Cause: One of the 1.5v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6829. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 3.3V temperature fault. Probable Cause: One of the 3.3v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6830. WBEM ProviderName: FPL_IndicationProvider. IO Backplane 5.0V temperature fault. Probable Cause: One of the 5.0v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 8293. WBEM ProviderName: FPL_IndicationProvider. IO Backplane -12.0V temperature fault. Probable Cause: One of the -12v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6831. WBEM ProviderName: FPL_IndicationProvider. IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is over temp and has shutdown. One failure and the Redundancy state is 'not redundant', after two power faults the redundancy state is 'insufficient'. Recommended Action: Check IO backplane power board. Faulted VRM is given by PS command. WBEM EventID: 6832. WBEM ProviderName: FPL_IndicationProvider. The local cell was unable to clear the link_off bit on at least one CC-CC link. Data field: return value of Phase3BackToBackPrep(). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4944. WBEM ProviderName: FPL_IndicationProvider. ArfOLAPreRendez() was unable to reach the added cell. Data field: bitmap of unreachable cells. Probable Cause: Firmware was unable to find a valid route to a cell being added by OLA. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4945. WBEM ProviderName: FPL_IndicationProvider. 78 WBEM Provider Event Tables