HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 62
Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
9751 Error 9753 Error 9754 Error 9755 Error 9768 Error 9801 Error 9832 Error 9849 Error 10116 Error 10117 Warning 10132 Error 10159 Warning 10209 Warning Windows: Predictive Failure in Memory (Critical). Probable Cause: You will receive this message if the system is correcting a lot of ECC single bit errors. It may mean that the module is about to fail, or environmental conditions in the server are causing more errors than usual. This event message will be generated for one of the following conditions 1500 single-bit errors on the same address in a 72 hour time period. 120 single-bit errors on the same DIMM (not the same address) in a 24 hour time period. 130 single-bit errors on the same DIMM (not the same address) in a 1 week time period. Recommended Action: If you receive this message, contact your support provider to determine if a predictive repair should be made. WBEM EventID: 1821. WBEM ProviderName: FPL_IndicationProvider. A rope parity error occurred. Probable Cause: An unexpected but random error occurred. Reboot the system. There is a problem with the system bus. Contact your HP representative to check the system bus. WBEM EventID: 1822. WBEM ProviderName: FPL_IndicationProvider. PCI card inaccessible due to bus error. Probable Cause: An unexpected but random error occurred. Recommended Action: Reboot the system. WBEM EventID: 1823. WBEM ProviderName: FPL_IndicationProvider. PCI card inaccessible due to device error. Probable Cause: An unexpected but random error occurred. Reboot the system. There is a problem with the system bus. Contact your HP representative to check the system bus. Check the system forward progress log (available from the Management Processor) for additional information about this problem. WBEM EventID: 1824. WBEM ProviderName: FPL_IndicationProvider. error reading bmc first boot token. Probable Cause: FW tried to read the first boot token and received a failure. Recommended Action: AC power cycle the system . If this doesn't work, contact HP support. WBEM EventID: 1825. WBEM ProviderName: FPL_IndicationProvider. An error occurred while enabling hashing in the platform cache. Probable Cause: An error return status. This could happen if the tree was corrupted or there was an error verifying the hashing setting. Recommended Action: reset the partition. WBEM EventID: 1842. WBEM ProviderName: FPL_IndicationProvider. It indicates loss of cell connectivity in the partition. Probable Cause: It will lead to cells performing RESET_FOR_RECONFIG after getting the error logs. WBEM EventID: 2448. WBEM ProviderName: FPL_IndicationProvider. Error building cell-level FW device tree. Probable Cause: Data field displays the status of creating the cell level device tree for use by firmware. See previous errors already reported. WBEM EventID: 2450. WBEM ProviderName: FPL_IndicationProvider. The NVRAM service was unable to satisfy an NVRAM allocation request. Probable Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear NVRAM and reset. WBEM EventID: 2499. WBEM ProviderName: FPL_IndicationProvider. The OS has registered an OS_INIT vector, but it has not passed the checksum. Probable Cause: The OS has registered an OS_INIT vector and checksum, but the checksum did not match the calculated value. Recommended Action: 1. Reboot2. Contact support. WBEM EventID: 8339. WBEM ProviderName: FPL_IndicationProvider. The RTC not updating its internal time registers. Probable Cause: Bad RTC chip on the PDH daughtercard. Recommended Action: Replace PDH daughtercard. WBEM EventID: 2512. WBEM ProviderName: FPL_IndicationProvider. Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has occurred on the MX2 module and PAA firmware has halted. Recommended Action: Contact your HP support personnel. WBEM EventID: 2740. WBEM ProviderName: FPL_IndicationProvider. fabric API is about to open the a link going out of the local cell. Probable Cause: An error prevented the use of a fabric link. Recommended Action: Collect IPMI event logs for more information regarding the failure. Contact your HP Support Representative to investigate the fabric subsystem. WBEM EventID: 2914. WBEM ProviderName: FPL_IndicationProvider. 62 WBEM Provider Event Tables