HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 83
recommended Paging File size using the HP System Management Home or use
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
12049 Warning 12050 Error 12069 Warning 12070 Warning 12088 Warning 12090 Warning 12091 Warning 12101 Error 12102 Error 12103 Error 12109 Warning 12119 Warning TPM failed initialization. Security features disabled. Probable Cause: Communication failure between the I/O board and the TPM. Recommended Action: replace the I/O board. Contact HP support. WBEM EventID: 5195. WBEM ProviderName: FPL_IndicationProvider. A CPU module's temperature has exceed the high temperature threshold or a CPU power module fault has occurred. As a result of this event, the CPU has been inhibited. The Cell must be powered off then on using the MP's PE command to clear. Probable Cause: A CPU module's temperature has exceed the high temperature threshold or a CPU power module fault has occurred. Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 5192. WBEM ProviderName: FPL_IndicationProvider. SFW detected an error while writing to stable store flash. Probable Cause: Cosmic radiation Bad flash part. Recommended Action: Reboot, if problem persists, contact HP support. WBEM EventID: 6861. WBEM ProviderName: FPL_IndicationProvider. Stable Store data is uninitialized or invalid. Probable Cause: Bad checksum on the stable store area. Cosmic radiation Bad flash part. Recommended Action: Reboot, if problem persists, contact HP support. WBEM EventID: 8288. WBEM ProviderName: FPL_IndicationProvider. Windows crash dump file has not been enabled. Probable Cause: The system has not been configured to save debugging information in the event of a system crash. Recommended Action: Configure writing debugging information using Windows Control Panel>System>Advance>Startup and Recovery. WBEM EventID: 5248. WBEM ProviderName: FPL_IndicationProvider. Windows paging file size or the free space of the memory dump target volume is too small. Probable Cause: The paging file or the free space of the memory dump target volume is not large enough to store the crash dump information in the event of a system crash. Recommended Action: Check the crash dump settings for the recommended Paging File size using the HP System Management Home Page or use Startup and Recovery under Windows System Properties. Also execute the disk cleanup to free some space on the target volume of the memory dump file. WBEM EventID: 5249. WBEM ProviderName: FPL_IndicationProvider. PCI interlock open with PCI power applied. Probable Cause: PCI interlock has been opened with PCI slot power on. Recommended Action: power down slot attempting to remove PCI card. WBEM EventID: 5230. WBEM ProviderName: FPL_IndicationProvider. Fault detected on low drop out regulator on I/O backplane. Probable Cause: A defective component could cause this fault. Recommended Action: Check the backplane. WBEM EventID: 5237. WBEM ProviderName: FPL_IndicationProvider. Fault detected on low drop out regulator on main backplane. Probable Cause: The specified low dropout regulator on the main backplane is reporting a fault. Recommended Action: Check the main backplane. WBEM EventID: 5238. WBEM ProviderName: FPL_IndicationProvider. Fault detected hot swap controller of specified core IO. Probable Cause: The hot swap controller for the specified core IO is reporting fault. Recommended Action: Check the specified core IO. WBEM EventID: 5250. WBEM ProviderName: FPL_IndicationProvider. An error occurred while retrieving the crossbar chip number. Probable Cause: System firmware had difficulty determining the crossbar number from the graph data structure. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 5251. WBEM ProviderName: FPL_IndicationProvider. One or more of the cells are not configured for Cell-Local Memory (CLM) mode. Probable Cause: The initial partition configuration may have not specified 100% Cell-Local Memory or may have been reconfigured incorrectly. Recommended Action: Reconfigure the partition or reset the CLM setting on one or more cells in your partition using the Partition Manager or ParCLI tools. WBEM EventID: 5259. WBEM ProviderName: FPL_IndicationProvider. Platform Events 83