Power on failed due to an SBL Scalable Blade Link mismatch. Probable Cause: Each

Page 101 highlights

14483 Error 14485 Error 14486 Error 14487 Error 14488 Error 14495 Warning 14512 Error 14516 Error 14517 Warning Power could not turn on because CPUs in the system or SBL Domain are mismatched. Probable Cause: The system/SBL domain has CPUs of different S/SPEC and/or a delta greater than 1 in core stepping. Recommended Action: Determine which CPU part number you want to keep, and remove those that don't match. DF from the CM> menu will display S/SPEC and stepping to help identify mismatch. When the CPUs all match try to power on again. WBEM EventID: 9903. WBEM ProviderName: FPL_IndicationProvider. The installed SBL is incompatible for the enclosure type, or blade bay. Probable Cause: Each SBL2/SBL4 is constructed for the precise width of the enclosure bays. SBL2-7000, SBL2E-7000, and SBL4-7000 are designed for the c7000 enclosure. SBL2-3000, SBL2E-3000, and SBL4-3000 are designed for the c3000 enclosure. The SBL2-7000 and SBL2-3000 must be installed with the monarch blade in bay 1, 3, 5, or 7. The SBL2E-7000 and SBL2E-3000 must be installed with the monarch blade in bay 2, 4, or 6. The SBL4 must be installed with the monarch blade in bay 1 or 5. This event is being generated because the installed SBL does not match the environment. Recommended Action: Change your installation to a supported configuration. WBEM EventID: 9904. WBEM ProviderName: FPL_IndicationProvider. Power on failed due to an SBL (Scalable Blade Link) mismatch. Probable Cause: Each SBL2/SBL4 is constructed for the precise width of the enclosure bays. SBL2-7000, SBL2E-7000, and SBL4-7000 are designed for the c7000 enclosure. SBL2-3000, SBL2E-3000, and SBL4-3000 are designed for the c3000 enclosure. The SBL2-7000 and SBL2-3000 must be installed with the monarch blade in bay 1, 3, 5, or 7. The SBL2E-7000 and SBL2E-3000 must be installed with the monarch blade in bay 2, 4, or 6. The SBL4 must be installed with the monarch blade in bay 1 or 5. This event is being generated because the installed SBL does not match the environment. Recommended Action: Change your installation to a supported configuration. Then attempt power on again. WBEM EventID: 9905. WBEM ProviderName: FPL_IndicationProvider. Firmware on the system is mismatched. Probable Cause: One of the FW types within the system has a mismatch across blades. Recommended Action: Use the SR command from the CM> menu or look in the iLO web GUI to identify the mismatched FW and bring it up to date with the rest of the system. WBEM EventID: 9906. WBEM ProviderName: FPL_IndicationProvider. Power failed to turn on due to mismatched firmware. Probable Cause: The revision of one of the ROMs in the system does not match the revision of its counterparts. One of the FW types within the system has a mismatch. Recommended Action: Use the iLO SR command from the CM> menu or look in the iLO web GUI to identify the mismatched FW and bring it up to date with the rest of the system. WBEM EventID: 9907. WBEM ProviderName: FPL_IndicationProvider. The primary system variables are uninitialized. Probable Cause: The primary system variables are uninitialized. Recommended Action: The system variables must be initialized. Please run SYSSET to initialize them. WBEM EventID: 9898. WBEM ProviderName: FPL_IndicationProvider. The CPU power pod is no longer powering the CPU. Probable Cause: The CPU power pod is no longer providing power to the CPU. It may not be plugged in to the sytem board, or it may have failed. Recommended Action: If not plugged into the system board, plug it in. Check that the connector is not loose. If not then you should replace the FRU. WBEM EventID: 9908. WBEM ProviderName: FPL_IndicationProvider. This blade has failed to show signs of boot. Probable Cause: Something has caused the blade to fail to boot. No BOOT_START event was detected from this blade. Could be the result of a corrupted SFW ROM, a failing processor, or a board failure of the QPI link. Recommended Action: At the next convenient opportunity power cycle the system power to all blades that are configured as part of a system with the failed blade. Look for other errors that may have been logged. Reflash the SFW. WBEM EventID: 9909. WBEM ProviderName: FPL_IndicationProvider. ICH Mezzanine card is missing. Probable Cause: The communications to the ICH MEZZ may have failed. Otherwise the ICH MEZZ is not present. Recommended Action: The system will fail to power on if there is no ICH MEZZ on the monarch blade. Please validate proper loading of the ICH MEZZ card if a pc on fails. WBEM EventID: 9910. WBEM ProviderName: FPL_IndicationProvider. Platform Events 101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Power could not turn on because CPUs in the system or SBL Domain are mismatched.
Probable Cause: The system/SBL domain has CPUs of different S/SPEC and/or a delta
greater than 1 in core stepping. Recommended Action: Determine which CPU part
number you want to keep, and remove those that don't match. DF from the CM>
menu will display S/SPEC and stepping to help identify mismatch. When the CPUs
all match try to power on again. WBEM EventID: 9903. WBEM ProviderName:
FPL_IndicationProvider.
Error
14483
The installed SBL is incompatible for the enclosure type, or blade bay. Probable Cause:
Each SBL2/SBL4 is constructed for the precise width of the enclosure bays. SBL2-7000,
SBL2E-7000, and SBL4-7000 are designed for the c7000 enclosure. SBL2-3000,
SBL2E-3000, and SBL4-3000 are designed for the c3000 enclosure. The SBL2-7000 and
SBL2-3000 must be installed with the monarch blade in bay 1, 3, 5, or 7. The
SBL2E-7000 and SBL2E-3000 must be installed with the monarch blade in bay 2, 4,
or 6. The SBL4 must be installed with the monarch blade in bay 1 or 5. This event is
being generated because the installed SBL does not match the environment.
Recommended Action: Change your installation to a supported configuration. WBEM
EventID: 9904. WBEM ProviderName: FPL_IndicationProvider.
Error
14485
Power on failed due to an SBL (Scalable Blade Link) mismatch. Probable Cause: Each
SBL2/SBL4 is constructed for the precise width of the enclosure bays. SBL2-7000,
SBL2E-7000, and SBL4-7000 are designed for the c7000 enclosure. SBL2-3000,
SBL2E-3000, and SBL4-3000 are designed for the c3000 enclosure. The SBL2-7000 and
SBL2-3000 must be installed with the monarch blade in bay 1, 3, 5, or 7. The
SBL2E-7000 and SBL2E-3000 must be installed with the monarch blade in bay 2, 4,
or 6. The SBL4 must be installed with the monarch blade in bay 1 or 5. This event is
being generated because the installed SBL does not match the environment.
Recommended Action: Change your installation to a supported configuration. Then
attempt power on again. WBEM EventID: 9905. WBEM ProviderName:
FPL_IndicationProvider.
Error
14486
Firmware on the system is mismatched. Probable Cause: One of the FW types within
the system has a mismatch across blades. Recommended Action: Use the SR command
from the CM> menu or look in the iLO web GUI to identify the mismatched FW and
bring it up to date with the rest of the system. WBEM EventID: 9906. WBEM
ProviderName: FPL_IndicationProvider.
Error
14487
Power failed to turn on due to mismatched firmware. Probable Cause: The revision
of one of the ROMs in the system does not match the revision of its counterparts.
One of the FW types within the system has a mismatch. Recommended Action: Use
the iLO SR command from the CM> menu or look in the iLO web GUI to identify
the mismatched FW and bring it up to date with the rest of the system. WBEM
EventID: 9907. WBEM ProviderName: FPL_IndicationProvider.
Error
14488
The primary system variables are uninitialized. Probable Cause: The primary system
variables are uninitialized. Recommended Action: The system variables must be
initialized. Please run SYSSET to initialize them. WBEM EventID: 9898. WBEM
ProviderName: FPL_IndicationProvider.
Warning
14495
The CPU power pod is no longer powering the CPU. Probable Cause: The CPU power
pod is no longer providing power to the CPU. It may not be plugged in to the sytem
board, or it may have failed. Recommended Action: If not plugged into the system
board, plug it in. Check that the connector is not loose. If not then you should replace
the FRU. WBEM EventID: 9908. WBEM ProviderName: FPL_IndicationProvider.
Error
14512
This blade has failed to show signs of boot. Probable Cause: Something has caused
the blade to fail to boot. No BOOT_START event was detected from this blade. Could
be the result of a corrupted SFW ROM, a failing processor, or a board failure of the
QPI link. Recommended Action: At the next convenient opportunity power cycle the
system power to all blades that are configured as part of a system with the failed
blade. Look for other errors that may have been logged. Reflash the SFW. WBEM
EventID: 9909. WBEM ProviderName: FPL_IndicationProvider.
Error
14516
ICH Mezzanine card is missing. Probable Cause: The communications to the ICH
MEZZ may have failed. Otherwise the ICH MEZZ is not present. Recommended
Action: The system will fail to power on if there is no ICH MEZZ on the monarch
blade. Please validate proper loading of the ICH MEZZ card if a pc on fails. WBEM
EventID: 9910. WBEM ProviderName: FPL_IndicationProvider.
Warning
14517
Platform Events
101