HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 70
Recommended Action: Contact HP Support personnel to check the XBC. WBEM
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
10569 Warning 10570 Warning 10571 Warning 10572 Warning 10573 Warning 10574 Warning 10617 Warning 10619 Warning 10620 Warning 10621 Warning 10622 Warning 10623 Warning 10625 Warning 10626 Warning Error finding the shortest route. Probable Cause: System Firmware encountered a problem while processing the crossbar fabric graphs. Recommended Action: Collect IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4888. WBEM ProviderName: FPL_IndicationProvider. Error writing the remote XBC routing register. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4889. WBEM ProviderName: FPL_IndicationProvider. Error enabling the routes on the remote XBC. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4890. WBEM ProviderName: FPL_IndicationProvider. Error writing the routing register on the local XBC. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4891. WBEM ProviderName: FPL_IndicationProvider. Error writing the local XBC routing registers to reach a remote cell. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4892. WBEM ProviderName: FPL_IndicationProvider. Error enabling the local XBC routes. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4893. WBEM ProviderName: FPL_IndicationProvider. SynchGraphs() failed during Arches Fabric Phase 4. Data field: return value from SynchGraphs(). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4524. WBEM ProviderName: FPL_IndicationProvider. VM_DeleteVertex() failed in SynchGraphs(). Data field: (vertex id 32) | (vertex type 56) | (return value from VM_DeleteVertex()). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4525. WBEM ProviderName: FPL_IndicationProvider. VM_DeleteEdge() failed in the Arches Fabric function SynchGraphs(). Data field:(vertex id1 32) | (vertex port1 48) | (vertex type1 56) | (vertex id2 0) | (vertex port2 16) | (vertex type2 24). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4526. WBEM ProviderName: FPL_IndicationProvider. Unexpected error when calling an Arches Fabric vertex module function. Data field: return value from vertex module function. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4527. WBEM ProviderName: FPL_IndicationProvider. Unexpected return from an Arches Fabric vertex module function while copying a cell's graph. Data field: return value from vertex module function. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4528. WBEM ProviderName: FPL_IndicationProvider. The checksum update for the PDT has failed. Probable Cause: The call to update the checksum for the PDT failed. The PDT will most likely be cleared upon reboot. Recommended Action: Reboot Upgrade SFW Contact HP support. WBEM EventID: 4529. WBEM ProviderName: FPL_IndicationProvider. The checksum in the memory area of NVM is bad. Probable Cause: The checksum in the memory area of NVM is bad. Recommended Action: Upgrade SFW Contact HP support. WBEM EventID: 4530. WBEM ProviderName: FPL_IndicationProvider. Checksum calculation failed. Probable Cause: The checksum calculation failed. The data field contains the address that the checksum calculation was attempted on. Recommended Action: Upgrade SFW Contact HP support. WBEM EventID: 4531. WBEM ProviderName: FPL_IndicationProvider. 70 WBEM Provider Event Tables