HP Integrity rx2800 rx2800 i2 User Service Guide - Page 14
Cooling subsystem, Power subsystem, Fan identification, Table 3
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Cooling subsystem Six fans cool the server. The fans are all redundant, hot swap capable, and interchangeable. If one fan unit fails, the others increase speed to compensate for the failure. The fan units are N+1, meaning that the server has six fan units, but can operate with five fan units running. Figure 4 Fan identification The power supplies have built-in fans and are not controlled by the BMC. Power subsystem The server supports 1+1 redundant power supply for high line (1200W/200~240VAC) and low line (800W/100~120VAC) in the data center and office friendly server versions. Power redundancy is identified the following table. Table 3 Power Supply Count 1 2 1 2 1 2 1 2 Voltage High Line (200-240) High Line (200-240) Low Line (100-120) Low Line (100-120) Low Line (100-120) Low Line (100-120) Low Line (100-120) Low Line (100-120) CPU 1 or 2 1 or 2 1 1 1 1 2 2 DIMM Count 24 or less 24 or less 12 or less 12 or less 12 or less 12 or less 8 or less 8 or less Memory Riser Count 1 to 4 1 to 4 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 Redundancy No Yes No Yes Impossible configuration Impossible configuration No Yes 14 Overview