HP LH4r HP Netserver LXr 8500 Installation Guide - Page 109
Attaching the Cable Management Arm
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Chapter 8 Rack Mounting the HP NetServer 12. Re-install the three power supplies into the HP NetServer. 13. Go to "Attaching the Cable Management Arm" before securing the HP NetServer in the rack. Attaching the Cable Management Arm The Cable Management Arm for the HP NetServer LXr 8500 can only be mounted on HP Systems racks. The HP NetServer's Cable Management Arm allows the cables, including the power cord, to move in and out with the HP NetServer chassis without being accidentally disconnected. See Figure 8-11. WARNING Before sliding the HP NetServer out of the rack, ensure the anti-tip foot is still extended from the front of the rack. A tip-over hazard exists, so never slide more than one component out of the rack at a time. 1. Ensure the HP NetServer LXr 8500 is pushed all the way into the rack. 2. At the rear of the HP NetServer, place rack nuts on the left column in the 13th and 18th holes above the baseline of the HP NetServer. See Figure 8-11. Left Rear of Rack "#" represents the EIA unit numbers on the rack columns. Eighteenth Hole from Bottom Thirteenth Hole from Bottom # # # # # # Attach nuts to this face of the left rear column. Bottom of NetServer Sixth Hole from Bottom Fourth Hole from Bottom Figure 8-11. Attaching the Rack Nuts to the Left Column 3. Match the inner flange mounting holes with the two threaded inserts in the rear of the HP NetServer. See Figure 8-12. 101