HP LH4r HP Netserver LXr 8500 Installation Guide - Page 163

of NetServer. Mark

Page 163 highlights

Chapter 13 Left Rear Alternative Rack Mounting Right Rear Studs on slides will mount through this face of columns. Studs on slides will mount through this face of columns. Left Front Right Front Stud on slide will mount in fifth hole from bottom of NetServer. Mark hole for reference. Bottom of NetServer Figure 13-4. Mounting Hole Placement for the Slides 7. Hold the template alongside the inside face of the left-rear rack column. 8. Mark the single hole indicated by the template for future reference. The template directs you to a single rack-column hole on the left-rear rack column. 9. Attach a slide to the left-front and left-rear columns: a. Position the slide inside the left-front and left-rear rack columns. See Figure 13-5. b. Ensure the front end of the slide -- the extending end when pulled -- faces the front of the rack. c. Insert the slide's two threaded studs into the marked holes on the sides of the left-front and left-rear rack columns. See Figures 13-4 and 13-5. 155

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203

Chapter 13
Alternative Rack Mounting
155
Right Rear
Studs on slides
will mount through
this face of columns.
Right Front
Bottom of
NetServer
Stud on slide will
mount in fifth
hole from bottom
of NetServer. Mark
hole for reference.
Left Front
Studs on slides
will mount through
this face of columns.
Left Rear
Figure 13-4. Mounting Hole Placement for the Slides
7.
Hold the template alongside the inside face of the left-rear rack column.
8.
Mark the single hole indicated by the template for future reference.
The template directs you to a single rack-column hole on the left-rear rack
column.
9.
Attach a slide to the left-front and left-rear columns:
a.
Position the slide inside the left-front and left-rear rack columns.
See
Figure 13-5.
b.
Ensure the front end of the slide -- the extending end when pulled --
faces the front of the rack.
c.
Insert the slide’s two threaded studs into the marked holes on the sides
of the left-front and left-rear rack columns. See Figures 13-4 and 13-5.