Brother International MD-611 Instruction Manual - English - Page 42

Daily, precautions

Page 42 highlights

* DIP switch functions DSW-1 Treadle specifications DSW-2 Motor pulley size DSW-3 Automatic presser lifter unit DSW-4 Needle stop position (Refer to note) DSW-5 DSW-6 DSW-7 DSW-8 Sewing machine type Max. speed ON Export specifications -- OFF Domestic specifications ON 090 (when max. speed is 4000 spm or less) OFF 0105 (when max. speed 4000 spm is exceeded) ON Used OFF Not used ON Needle stops at up position when treadle is returned to neutral position. OFF Needle stops at down position when treadle is returned to neutral position. ON 2-needle (B842, B845, 8847, B848, B872, B875, etc.) OFF 1-needle (8737, B791, 8774, 8201, etc.) Set according to following table. Note: When the operation panel is connected, the operation panel settings will have the priority regardless of the DSW-4 set- tings. * DSW-6, DSW-7, DSW-8 settings DSW-6 DSW-7 DSW-8 OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON ON ON ON Max. speed 1000 spm 2000 spm 2500 spm 3000 spm 3500 spm 4000 spm 4500 spm 4700 spm Note: The max. speed is 4500 spm when DSW-2 is set to ON. The max. speed is 4000 spm when DSW-5 is set to ON. 3.4 Daily precautions * Periodically remove the dust on the dustproof cover. Failure to do so could cause the motor to overheat and create a hazardous state. * Turn off the main power when not using the product for a long time. - 30 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

*
DIP
switch
functions
DSW-1
DSW-2
Treadle
specifications
ON
Export
specifications
--
OFF
Domestic
specifications
Motor
pulley
size
ON
090
(when
max.
speed
is
4000
spm
or
less)
OFF
0105
(when
max.
speed
4000
spm
is
exceeded)
DSW-3
Automatic
presser
lifter
unit
ON
Used
OFF
Not
used
DSW-4
Needle
stop
position
(Refer
to
note)
ON
Needle
stops
at
up
position
when
treadle
is
returned
to
neutral
position.
OFF
Needle
stops
at
down
position
when
treadle
is
returned
to
neutral
position.
DSW-5
Sewing
machine
type
ON
2
-needle
(B842,
B845,
8847,
B848, B872,
B875,
etc.)
OFF
1
-needle
(8737,
B791,
8774,
8201,
etc.)
DSW-6
DSW-7
DSW-8
Max.
speed
Set
according
to
following
table.
Note:
When
the
operation
panel
is
connected,
the
operation
panel
settings
will
have
the
priority
regardless
of
the
DSW-4
set-
tings.
*
DSW-6, DSW-7,
DSW-8
settings
DSW-6
DSW-7
DSW-8
Max.
speed
OFF
OFF
OFF
1000
spm
ON
OFF
OFF
2000
spm
OFF
ON
OFF
2500
spm
ON
ON
OFF
3000
spm
OFF
OFF
ON
3500
spm
ON
OFF
ON
4000
spm
OFF
ON
ON
4500
spm
ON
ON
ON
4700
spm
Note:
The
max.
speed
is
4500
spm
when
DSW-2
is
set
to
ON.
The
max.
speed
is
4000
spm
when
DSW-5
is
set
to
ON.
3.4
Daily
precautions
*
Periodically
remove
the
dust
on
the
dustproof
cover.
Failure
to
do
so
could
cause
the
motor
to
overheat
and
create
a
hazardous
state.
*
Turn
off
the
main
power
when
not
using
the
product
for
a
long
time.
-
30
-