• If the array status LED is solid or blinking amber: a In the AMW, select the Summary tab, and click on Storage Array needs attention. Follow the listed procedures in the recovery guru(s) and wait for up to 5 minutes to check if the LED has turned blue. See "Recovery Guru" on page 223. b If following the recovery guru procedures does not solve the problem, complete the following procedure to further troubleshoot the array. c Turn off the host server as appropriate. d Remove the RAID controller module and verify that the pins on backplane and RAID controller module are not bent. See "Removing a RAID Controller Module Blank" on page 197. e Reinstall the RAID controller module and wait for 30 seconds. See "Installing a RAID Controller Module" on page 200. f Check the RAID controller module status LED. g Replace the RAID controller module. h Turn on the host server. If the problem is not resolved, see "Getting Help" on page 253. • If the link status LEDs are not green, see "Troubleshooting Array and Expansion Enclosure Connections" on page 247. a Turn off the server, storage arrays, and expansion enclosures. b Reseat the RAID controller module and reconnect cables on the storage array and the server. c Restart the storage array and wait until the array is fully booted. d Turn on the server. e Check the link status LED. If the link status LED is not green, replace the cables. If the problem is not resolved, see "Getting Help" on page 253. Troubleshooting: Your Array 245