Dell PowerVault MD3200 Owner's Manual - Page 247

Troubleshooting Array and Expansion Enclosure Connections

Page 247 highlights

Troubleshooting Array and Expansion Enclosure Connections 1 Verify that the RAID controller module port link status LED and the RAID controller module status LED are solid green for each port that is connected to a cable. If the LEDs are not solid green, see "Planning: RAID Controller Modules" on page 29. 2 Ensure that all the cables are attached correctly according to array mode you selected. 3 Turn off the server, storage array, and expansion enclosures. 4 Reseat the RAID controller module and reconnect cables on the storage array and the server. 5 Turn on the expansion arrays and then the storage array and wait until the system is fully booted. 6 Turn on the server. 7 Check the link status LED. If the link status LED is not green, replace the cables. If the problem is not resolved, see "Getting Help" on page 253. 8 Reboot the host server. NOTE: You must turn off the host server before resetting the cables on the storage array or expansion enclosure. If the problem is not resolved, see "Getting Help" on page 253. Troubleshooting: Your Array 247

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260

Troubleshooting: Your Array
247
Troubleshooting Array and Expansion Enclosure
Connections
1
Verify that the RAID controller module port link status LED and the
RAID controller module status LED are solid green for each port that is
connected to a cable. If the LEDs are not solid green, see "Planning: RAID
Controller Modules" on page 29.
2
Ensure that all the cables are attached correctly according to array mode
you selected.
3
Turn off the server, storage array, and expansion enclosures.
4
Reseat the RAID controller module and reconnect cables on the storage
array and the server.
5
Turn on the expansion arrays and then the storage array and wait until the
system is fully booted.
6
Turn on the server.
7
Check the link status LED. If the link status LED is not green, replace the
cables.
If the problem is not resolved, see "Getting Help" on page 253.
8
Reboot the host server.
NOTE:
You must turn off the host server before resetting the cables on
the storage array or expansion enclosure.
If the problem is not resolved, see "Getting Help" on page 253.