HP Cisco Nexus 5000 Cisco NX-OS System Messages Reference (OL-15994-03, July 2 - Page 517
You can verify available power and current usage using the command 'show
View all HP Cisco Nexus 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 517 highlights
Chapter 2 System Messages and Recovery Procedures PLATFORM Messages Send document comments to [email protected] Error Message PLATFORM-2-MOD_ALL_PWRDN_NOXBAR: All modules powered down due to non-availability of xbar modules Explanation All modules in switch are powered down because all xbar modules are offline. Recommended Action Enter a 'show module', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors.At leastone xbar module has to be for modules to function. Error Message PLATFORM-2-MOD_DETECT: Module [dec] detected (Serial number [chars]) Module-Type [chars] Model [chars] Explanation A new module in slot [decimal digit] is detected. Recommended Action No action is required. Error Message PLATFORM-2-MOD_PWRDENY: Module [dec] can not be powered up due to insufficient power (Serial number [chars]) Explanation Available power in power supplies is not sufficient to power up the module. Recommended Action You can verify available power and current usage using the command 'show env power'. Refer to power supply document on how to increase power supply capacity. Error Message PLATFORM-2-MOD_PWRDN: Module [dec] powered down (Serial number [chars]) Explanation The module in slot [decimal digit] is powered down. Recommended Action Enter a 'show module', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors. Error Message PLATFORM-2-MOD_PWRFAIL: Module [dec] failed to power up (Serial number [chars]) Explanation The module in slot [decimal digit] failed to power up. Recommended Action Enter a 'show platform internal all module [decimal digit]' and to collect more information. Error Message PLATFORM-2-MOD_PWRFAIL_EJECTORS_OPEN: Both ejectors open, Module [dec] will not be powered up (Serial number [chars]) Explanation The module cannot be powered up because both ejectors are open. Recommended Action Enter a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information. OL-15994-03 Cisco NX-OS System Messages Reference 2-479