HP Cisco Nexus 5000 Cisco NX-OS System Messages Reference (OL-15994-03, July 2 - Page 668
SVC-3, Services Module.
View all HP Cisco Nexus 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 668 highlights
SVC Messages Chapter 2 System Messages and Recovery Procedures Send document comments to [email protected] Error Message SVC-2-SVC_SYSLOG_PATH_FAILURE: System health detected SVC packet path failure for [chars]. Explanation The CSM has been brought down by the system health monitor. The system Health has detected a failure in the packet path between the SVC interface on the CSM and the backplane. This The system Health test is run periodically. Recommended Action Issue a no shutdown on the SVC interface to bring the node back online. If a subsequent packet path failure occurs, the CSM module should be replaced. SVC-3 Error Message SVC-2-SVC_SYSLOG_URIFS_FAILURE: [chars] is unreachable for reason: [chars] Explanation SVC interface modflash is not accessible. Modflash is the name of the file system local to the SVC interface, and is typically used for coredumps and temporary file transfers. Recommended Action Please shutdown and bring up the SVC interface in question to regain access to the modflash file system. Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_ACTIVATE_CLUSTER_IP_FAILED ) Activate cluster IP failed [chars] Explanation The system is unable to activate the cluster IP for the config node. It will not be possible to execute configuration commands. Recommended Action 1. Shutting the interfaces of the node will force this node out of the cluster and cause another node to become the config node, which should restore the ability to execute configuration commands. 2. If the error persists, re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code. 4. If the error continues, ask IBM Product Support for assistance. Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_FAILURE ) Battery Failed [chars] Explanation The battery module on the Caching Services Module has failed. The nodes on the CSM will have shutdown. Other log entries may accompany this error. Recommended Action Reload the Caching Services Module. If the error persists, replace the Caching Services Module. 2-630 Cisco NX-OS System Messages Reference OL-15994-03