HP Cisco Nexus 5000 Cisco NX-OS System Messages Reference (OL-15994-03, July 2 - Page 762
Compact flash firmware CRC checksum might be bad on this module.
View all HP Cisco Nexus 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 762 highlights
SYSTEMHEALTH Messages Chapter 2 System Messages and Recovery Procedures Send document comments to [email protected] Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_PROCESS_ERRORS: Compact flash firmware CRC checksum procedure failed on module [dec]. Reason [dec] Explanation Compact flash firmware CRC checksum procedure failed. Recommended Action Try restarting the cf-crc-check using system health clear-errors module cf-crc-check. If the condition still persists, schedule a downtime and replace the compact flash on the affected module. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_TEST_FAILING: Compact flash firmware CRC checksum validation starting to fail on module [dec]. Explanation Compact flash firmware CRC checksum might be bad on this module. Recommended Action Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_RECALLED: Compact Flash on module [dec] was recalled. Explanation The Compact flash model has data retention issues and needs to be replaced. Recommended Action Please schedule a downtime and replace the compact flash on this module. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_INTERN_ERRORS: Compact Flash firmware re-flash procedure cannot proceed due to internal errors on module [dec]. Explanation Compact flash firmware re-flash procedure ended up in errors. Recommended Action Try restarting the test using system health clear-errors module cf-re-flash. If the condition still persists, schedule a downtime and replace the compact flash on the affected module. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_TEST_FAILING: Compact flash firmware refresh procedure starting to fail on module [dec]. Explanation Compact flash might be dead on this module. Recommended Action Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_UNRESPONSIVE: Recalled Compact Flash on module [dec] is unresponsive. Explanation The Compact flash model has data retention issues and needs to be replaced. Recommended Action Please schedule a downtime and replace the compact flash on this module. 2-724 Cisco NX-OS System Messages Reference OL-15994-03