Yamaha A5000 Owner's Manual - Page 217

INITIALIZE, Knob 5, Operation]

Page 217 highlights

About the COMMANDS Knob 5 [ Turn] Sample Specifies the sample (sample bank) to be transmitted via the Bulk Dump operation. All samples (sample banks) in memory can be selected. • This parameter can only be used when the Bulk Type is set to Sample. [ Press] EXEC&CONT Press this knob to call the bulk dump confirmation display. Press Knob 5 (YES) to actually execute the bulk dump operation. INITIALIZE [COMMAND/EXIT] Button → Knob 1 to highlight display line 2 → Press Knob 5. Use this screen to initialize one or all memory-resident programs. • Initialization removes all sample assignments (sets all ToPgm switches to OFF), clears all Easy Edit settings, and returns the EFFECT, SETUP, and CONTROL settings to the initial values selected at the REGISTER page (page 214). (If you have not set any REGISTER values, then EFFECT, SETUP, and CONTROL settings revert to their factory defaults) [Operation] 1. Select the Init Type (page 217). 2. If the Init Type is OneProgram, specify the program to be initialized (page 217). 3. Specify whether to initialize from the Register settings, or from the factory preset settings (page 217). 4. Press Knob 1 (EXEC) or Knob 5 (EXEC&CONT), and the initialize confirmation display will appear. Press Knob 5 (YES) to execute the initialize operation. • If Knob 1 (EXEC) is used to execute the command, the display previous to the command menu will be recalled after execution has finished. If Knob 5 (EXEC&CONT) is used to execute the command, the bulk dump display will be retained so you can continue and perform further bulk dump operations. Knob 2 [ Turn] Init Type Determines whether a single program or all programs will be initialized. [Range] AllPrograms, OneProgram • AllPrograms ... Initialize all programs. • OneProgram ... Initialize only the program selected by Knob 3. Knob 3 [ Turn] Program Selects a single program to be initialized. [Range] 001 - 128 • This parameter can only be used if Init Type is set to OneProgram. Knob 5 [ Turn] InitTo Specifies the type of initialization to be performed. [Range] RegisteredSet, FactorySet • RegisteredSet ... The values registered via the REGISTER command are used for initialization. • FactorySet ... The factory preset values are used for initialization. [ Press] EXEC&CONT Press this knob to call the initialize confirmation display. Press Knob 5 (YES) to actually execute the initialize operation. Turn action Press action Knob 1 - EXEC Knob 2 Init Type - Knob 3 Program - Knob 4 - - Knob 5 InitTo EXEC&CONT 217 q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q A5000/A4000 • Chapter 9 COMMAND

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
A5000/A4000 •
Chapter 9
COMMAND
217
About the COMMANDS
Knob 5
[
Turn]
Sample
Specifies the sample (sample bank) to be transmitted via
the Bulk Dump operation.
All samples (sample banks) in memory can be selected.
This parameter can only be used when the Bulk Type
is set to Sample.
[
Press] EXEC&CONT
Press this knob to call the bulk dump confirmation dis-
play. Press Knob 5 (YES) to actually execute the bulk
dump operation.
INITIALIZE
[COMMAND/EXIT] Button
Knob 1 to highlight display line 2
Press Knob 5.
Use this screen to initialize one or all memory-resident pro-
grams.
• Initialization removes all sample assignments (sets all ToPgm
switches to OFF), clears all Easy Edit settings, and returns the
EFFECT, SETUP, and CONTROL settings to the initial values
selected at the REGISTER page (page 214). (If you have not set
any REGISTER values, then EFFECT, SETUP, and CONTROL set-
tings revert to their factory defaults)
[Operation]
1.
Select the Init Type (page 217).
2.
If the Init Type is OneProgram, specify the program to be initialized
(page 217).
3.
Specify whether to initialize from the Register settings, or from the
factory preset settings (page 217).
4.
Press Knob 1 (EXEC) or Knob 5 (EXEC&CONT), and the initialize
confirmation display will appear. Press Knob 5 (YES) to execute
the initialize operation.
If Knob 1 (EXEC) is used to execute the command, the display
previous to the command menu will be recalled after execution
has finished. If Knob 5 (EXEC&CONT) is used to execute the
command, the bulk dump display will be retained so you can
continue and perform further bulk dump operations.
Knob 2
[
Turn]
Init Type
Determines whether a single program or all programs will
be initialized.
[Range]
AllPrograms, OneProgram
AllPrograms
... Initialize all programs.
OneProgram
... Initialize only the program
selected by Knob 3.
Knob 3
[
Turn]
Program
Selects a single program to be initialized.
[Range]
001 — 128
This parameter can only be used if Init Type is set to
OneProgram.
Knob 5
[
Turn]
InitTo
Specifies the type of initialization
to be performed.
[Range]
RegisteredSet, FactorySet
RegisteredSet
... The values registered via the
REGISTER command are used for initializa-
tion.
FactorySet
... The factory preset values are used
for initialization.
[
Press] EXEC&CONT
Press this knob to call the initialize confirmation display.
Press Knob 5 (YES) to actually execute the initialize
operation.
Knob 1
Knob 2
Knob 3
Knob 4
Knob 5
Turn
action
Init Type
Program
InitTo
Press
action
EXEC
EXEC&CONT