Brother International DCP1000 Service Manual - Page 145
WSW01, pulse, setting, Selectors, generation, Break, length, dialing, Inter, digit, pause
UPC - 012502565796
View all Brother International DCP1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW01 (Dial pulse setting) Function Setting and Specifications Dial pulse generation mode Break time length in pulse dialing Inter-digit pause Switching between pulse (DP) and tone (PB) dialing, by the function switch Default dialing mode, pulse (DP) or tone (PB) dialing No. 1 2 00 : 01 : 10 : 11 : No. 3 4 00 : 01 : 10 : 11 : No. 5 6 00 : 01 : 10 : 11 : 0: Yes 0: PB N N+1 10-N N 60 ms 67 ms 40 ms (for 16 PPS) 64 ms (at 106-ms intervals) 800 ms 850 ms 950 ms 600 ms 1: No 1: DP NOTE: In models supporting no pulse (DP) dialing mode (e.g., U.S.A. version), selector 7 takes no effect even if it may be set. • Selectors 1 and 2: Dial pulse generation mode These selectors set the number of pulses to be generated in pulse dialing. N: Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.) N + 1: Dialing "N" generates "N + 1" pulses. 10 - N: Dialing "N" generates "10 - N" pulses. • Selectors 3 and 4: Break time length in pulse dialing These selectors set the break time length in pulse dialing. (Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.) Break time length set by selectors 3 and 4 < > . . --> < > 1 6 1 _) "3" Inter-digit pause set by selectors 5 and 6 2