• Preparation Prior to proceeding to the disassembly procedure, (1) Unplug - the modular jack of the telephone line (only for models equipped with the fax function), - the power cord, - the modular jack of the curled cord (and remove the handset), - the PC interface cable (parallel cable or USB cable) if connected (Not shown below), and - the modular jack of an external telephone set if connected (Not shown below). (2) Remove - the paper support, - the paper tray, and - the drum unit (with the toner cartridge loaded) Drum unit (with toner cartridge loaded) Paper support Power cord Telephone line cord (Only for models w/ fax function) O pee Paper tray • How to Access the Object Component • On the next page is a disassembly order flow which helps you access the object components. To remove the gear drive unit, for example, first find it on the flow and learn its number m (10 this case). You need to remove parts numbered 41), and so as to access the gear drive unit. • Unless otherwise specified, the disassembled parts or components should be reassembled in the reverse order of removal. 4-4