transmission.
UPC - 012502565796
View all Brother International DCP1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 170 highlights
Selector No. 1 2 3 4 5 8 WSW24 (TAD setting 2) Function Setting and Specifications Not used. Time length from CIVIL ON to start of pseudo ring backtone transmission Attenuator for playback of ICM/ OGM to the line (Selectable from the range of 0-15 dB) No. 3 4 00 : 01 : 10 : 11 : 4 sec. 3 sec. 2 sec. 1 sec. 0: 0 dB 0: 0 dB 0: 0 dB 0: 0 dB 1: 8 dB 1: 4 dB 1: 2 dB 1: 1 dB • Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission These selectors set the length of time from CML-ON up to the start of pseudo ring backtone transmission. In those versions which have an OGM facility, the settings made by these selectors also apply to the length of time from CML-ON up to the start of OGM transmission. • Selectors 5 through 8: Attenuator for playback of ICMIOGM to the line Setting two or more selectors to "1" produces addition of attenuation assigned to each selector. This setting will not be limited by selector 8 of WSW23. 27