Brother International DCP1000 Service Manual - Page 177
WSW32, Function, setting, Selectors, Default, resolution, contrast, WSW33
UPC - 012502565796
View all Brother International DCP1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
Selector No. 1 4 5 6 7 8 WSW32 (Function setting 10) Function Setting and Specifications Not used. Default resolution Default contrast No. 5 6 0 0 : 0 1 : 1 0 : 1 1 : No. 7 8 0 X: 1 0 : 1 1 : Standard Fine Super fine Photo Automatic Super light Super dark • Selectors 5 and 6: Default resolution These selectors set the default resolution which applies when the equipment is powered up or completes a transaction. • Selectors 7 and 8: Default contrast These selectors set the default contrast which applies when the equipment is powered up or completes a transaction. Selector No. 1 5 6 7 8 WSW33 (Function setting 11) Function Setting and Specifications Not used. Report output of polled transmission requests Not used. 0: Yes 1: No NOTE: Selector 6 is not applicable to American versions. 34