WSW18, Function, setting, Selectors, Detection, enabled, sound, monitoring
UPC - 012502565796
View all Brother International DCP1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 165 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW18 (Function setting 3) Function Setting and Specifications Not used. No. 2 3 Detection enabled time for CNG and no tone 0 0: 0 1: 1 0: 1 1: 40 sec. 0 sec. 5 sec. 80 sec. (No detection) Not used. Registration of station ID Tone sound monitoring 0: No. 7 0 1 1 Permitted 1: Prohibited 8 X : No monitoring 0 : Up to phase B at the calling station only 1 : All transmission phases both at the calling and called stations • Selectors 2 and 3: Detection enabled time for CNG and no tone After the line is connected via the external telephone or by picking up the handset of the facsimile equipment, the equipment can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 of WSW20 is set to "1." • Selectors 7 and 8: Tone sound monitoring These selectors set monitoring specifications of the tone sound inputted from the line. 22