equipment.
UPC - 012502565796
View all Brother International DCP1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 171 highlights
Selector No. 1 2 3 4 5 7 8 WSW25 (TAD setting 3) Function Delay time for starting detection of voice signal Detection level for no voice signal Pause between paging number and PIN Not used. Setting and Specifications No. 1 2 00 0 1 : : 0 sec. 8 sec. 1 0 : 16 sec. 1 1 : 24 sec. No. 3 4 0 0 : 0 1 : 10 : 1 1 : -43 dB (A) -46 dB (B) -49 dB (C) -51 dB (D) No. 5 6 7 0 0 0 : 0 0 1 : 0 1 0 : 0 1 1 : 1 0 0 : 1 0 1 : 1 1 0 : 1 1 1 : 2 sec. 4 sec. 6 sec. 8 sec. 10 sec. 12 sec. 14 sec. 16 sec. NOTE: Selectors 1 through 4 are not applicable to the U.S.A. versions. NOTE: Selectors 5 through 7 are applicable to those models equipped with a built-in TAD. • Selectors 1 and 2: Delay time for starting detection of voice signal These selectors take effect only in TAD mode (when the external TAD is connected to the equipment). The equipment delays starting detection of the voice signal by the time length specified by these selectors. The total length of the delay time specified by these selectors and the maximum waiting time specified by WSW21 (selectors 1 through 5) should not exceed 40 seconds. • Selectors 3 and 4: Detection level for no voice signal These selectors set the detection level for no voice signal in the TAD mode (when the external TAD is connected to the equipment). • Selectors 5 through 7: Pause between paging number and PIN These selectors set the pause time between a telephone number being paged and PIN (private identification number) for the paging feature. 28