HP Armada 1100 Armada 1100 Family of Personal Computers Maintenance and Servic - Page 20
location 0E Hex - 3F Hex failed., Table 2-2. Fatal Error Messages
View all HP Armada 1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Table 2-2. Fatal Error Messages Message Description Beep Code CMOS RAM test failed A walking bit test of CMOS RAM location 0E (Hex) - 3F (Hex) failed. 3 DMA controller faulty A sequential read/write of the transfer count and transfer address registers within the primary and secondary DMA controllers failed. 4 Faulty DMA page registers A walking bit read/write of the 16 DMA controller page registers starting at location 80 Hex failed. 0 Faulty refresh circuits A continuous read/write test of port 61h found that bit 4 (Refresh Detect) failed to toggle within an allotted amount of time. 1 Interrupt controller failed A sequential read/write of various Interrupt Controller registers failed. 5 ROM checksum incorrect A checksum of the ROM BIOS does not match the byte value at F000:FFFF. 2 RAM error at location xxxx RAM error occurred during memory test. None Parity error at unknown location Parity error occurred. None