HP Armada 1100 Armada 1100 Family of Personal Computers Maintenance and Servic - Page 27

Table 2-10. Hard Drive Test Error Codes

Page 27 highlights

Table 2-9. Serial Test Error Codes Error Code Description Recommended Action 1101 - xx Serial port test 1. Check port configuration failed 2. Replace the system board and retest. Table 2-10. Hard Drive Test Error Codes Error Code Description Recommended Action 1701 - xx Hard drive format The following steps apply to error test failed codes 1701 - xx through 1736 - xx: 1702 - xx 1703 - xx Hard drive read test failed Hard drive write/ read/compare test failed 1. Run the Diagnostics Utilities and verify drive type. 2. Replace the hard drive and retest. 3. Replace the system board and retest. 1704 - xx Hard drive random seek test failed 1705 - xx Hard drive controller test failed 1706 - xx Hard drive ready test failed 1707 - xx Hard drive recalibration test failed 1708 - xx Hard drive format bad track test failed 1709 - xx Hard drive reset controller test failed 1710 - xx Hard drive park head test failed 1715 - xx Hard drive head select test failed 1716 - xx Hard drive conditional format test failed 1717 - xx Hard drive ECC * test failed 1719 - xx Hard drive power mode test failed 1724 - xx Network preparation test failed 1736 - xx Drive monitoring test failed ECC = Error Correction Code

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

Table 2-9. Serial Test Error Codes
===========================================================================
Error Code
Description
Recommended Action
===========================================================================
1101 - xx
Serial port test
1. Check port configuration
failed
2. Replace the system board and retest.
===========================================================================
Table 2-10. Hard Drive Test Error Codes
===========================================================================
Error Code
Description
Recommended Action
===========================================================================
1701 - xx
Hard drive format
The following steps apply to error
test failed
codes 1701 - xx through 1736 - xx:
1702 - xx
Hard drive read test
1. Run the Diagnostics Utilities
failed
and verify drive type.
2. Replace the hard drive and retest.
1703 - xx
Hard drive write/
3. Replace the system board and
read/compare test
retest.
failed
1704 - xx
Hard drive random
seek test failed
1705 - xx
Hard drive
controller test
failed
1706 - xx
Hard drive ready
test failed
1707 - xx
Hard drive
recalibration test
failed
1708 - xx
Hard drive format
bad track test
failed
1709 - xx
Hard drive reset
controller test
failed
1710 - xx
Hard drive park
head test failed
1715 - xx
Hard drive head
select test failed
1716 - xx
Hard drive
conditional format
test failed
1717 - xx
Hard drive ECC *
test failed
1719 - xx
Hard drive power
mode test failed
1724 - xx
Network preparation
test failed
1736 - xx
Drive monitoring
test failed
---------------------------------------------------------------------------
* ECC = Error Correction Code
===========================================================================