HP Armada 1100 Armada 1100 Family of Personal Computers Maintenance and Servic - Page 30
ECG/VGC ROM checksum, Run the Diagnostics Utilities.
View all HP Armada 1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Error Code Description Recommended Action 2419 - xx ECG/VGC ROM checksum The following steps apply to error test failed codes 2402 - xx through 2456 - xx: 2421 - xx 2422 - xx ECG/VGC 640 x 200 graphics mode test failed ECG/VGC 640 x 350 16 color set test failed 1. Run the Diagnostics Utilities. 2. Disconnect external monitor and retest with internal LCD monitor. 3. Replace the display assembly and retest. 4. Replace the system board and retest. 2423 - xx ECG/VGC 640 x 350 64 color set test failed 2431 - xx 640 x 480 graphics test failure 2432 - xx 320 x 200 graphics (256 color mode) test failure 2448 - xx Advanced VGA Controller test failed 2451 - xx 132-column Advanced VGA test failed 2456 - xx Advanced VGA 256 Color test failed 2458 - xx Advanced VGA BitBLT Replace the system board and retest. test 2468 - xx Advanced VGA DAC test 2477 - xx Advanced VGA data path test 2478 - xx Advanced VGA BitBLT test 2480 - xx Advanced VGA Linedraw test