Panasonic WJ-HD716/1000 Installation Guide - Page 141

Extension unit: EXTx HDD SKIP

Page 141 highlights

Content Error log Network Log Single mode format failure RAID5 format failure RAID6 format failure RAID5 1 down RAID5 2 down RAID6 1 down RAID6 2 down RAID6 3 down HDD smart warning HDD hour meter warning HDD SKIP warning Remove auto links (per HDD) Remove auto links (per recorder or extension unit) Recorder: MAIN-y SINGLE - FORMAT ERROR Extension unit: EXTx-y SINGLE FORMAT ERROR Recorder: MAIN RAID5 - FORMAT ERROR Extension unit: EXTx RAID5 FORMAT ERROR Recorder: MAIN RAID6 - FORMAT ERROR Extension unit: EXTx RAID6 FORMAT ERROR Recorder: MAIN RAID5 1DOWN - Extension unit: EXTx RAID5 1 DOWN Recorder: MAIN RAID5 2DOWN - Extension unit: EXTx RAID5 2 DOWN Recorder: MAIN RAID6 1DOWN - Extension unit: EXTx RAID6 1 DOWN Recorder: MAIN RAID6 2DOWN - Extension unit: EXTx RAID6 2 DOWN Recorder: MAIN RAID6 3DOWN - Extension unit: EXTx RAID6 3 DOWN Recorder: MAIN-y SMART - WARNING Extension unit: EXTx-y SMART WARNING Recorder: MAIN-y HOUR - METER WARNING Extension unit: EXTx-y HOUR METER WARNING • Per HDD (In the single mode) - Recorder: MAIN-y HDD SKIPHDD Extension unit: EXTx-y HDD SKIP • Per unit (in the RAID 5 or RAID 6 mode) Recorder: MAIN HDD SKIP Extension unit: EXTx HDD SKIP Recorder: MAIN-y LOGICALLY - REMOVED Extension unit: EXTx-y LOGICALLY REMOVED Recorder: MAIN LOGICALLY - REMOVED Extension unit: EXTx LOGICALLY REMOVED Display on Monitor 2 F-FAIL Output from the connector at the rear panel HDD error F-FAIL HDD error F-FAIL HDD error 1DOWN 2DOWN 1DOWN 2DOWN 3DOWN SMART HDD error HDD error HDD error HDD error HDD error HDD error H-METER HDD error - - REMOVE HDD error REMOVE HDD error 141

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

141
Content
Error log
Network Log
Display on
Monitor 2
Output from the
connector at
the rear panel
Single mode format failure
Recorder: MAIN-y SINGLE
FORMAT ERROR
Extension unit: EXTx-y SINGLE
FORMAT ERROR
F–FAIL
HDD error
RAID5 format failure
Recorder: MAIN RAID5
FORMAT ERROR
Extension unit: EXTx RAID5
FORMAT ERROR
F–FAIL
HDD error
RAID6 format failure
Recorder: MAIN RAID6
FORMAT ERROR
Extension unit: EXTx RAID6
FORMAT ERROR
F–FAIL
HDD error
RAID5 1 down
Recorder: MAIN RAID5 1DOWN
Extension unit: EXTx RAID5 1
DOWN
1DOWN
HDD error
RAID5 2 down
Recorder: MAIN RAID5 2DOWN
Extension unit: EXTx RAID5 2
DOWN
2DOWN
HDD error
RAID6 1 down
Recorder: MAIN RAID6 1DOWN
Extension unit: EXTx RAID6 1
DOWN
1DOWN
HDD error
RAID6 2 down
Recorder: MAIN RAID6 2DOWN
Extension unit: EXTx RAID6 2
DOWN
2DOWN
HDD error
RAID6 3 down
Recorder: MAIN RAID6 3DOWN
Extension unit: EXTx RAID6 3
DOWN
3DOWN
HDD error
HDD smart warning
Recorder: MAIN-y SMART
WARNING
Extension unit: EXTx-y SMART
WARNING
SMART
HDD error
HDD hour meter warning
Recorder: MAIN-y HOUR
METER WARNING
Extension unit: EXTx-y HOUR
METER WARNING
H–METER
HDD error
HDD SKIP warning
• Per HDD (In the single mode)
Recorder: MAIN-y HDD
SKIPHDD
Extension unit: EXTx-y HDD
SKIP
• Per unit (in the RAID 5 or
RAID 6 mode)
Recorder: MAIN HDD SKIP
Extension unit: EXTx HDD SKIP
Remove auto links (per
HDD)
Recorder: MAIN-y LOGICALLY
REMOVED
Extension unit: EXTx-y
LOGICALLY REMOVED
REMOVE
HDD error
Remove auto links (per
recorder or extension unit)
Recorder: MAIN LOGICALLY
REMOVED
Extension unit: EXTx
LOGICALLY REMOVED
REMOVE
HDD error