Symptom Cannot control the camera. Alarm operations are not activated. The "VIDEO LOSS" indication is displayed. The "THERMAL" indication is displayed. The clock loses time. The extension unit is not recognized (even when connecting the extension unit). Check item/Remedy Ref. Page • Is the user level of the current login user allowed to control the camera? 108 Check the settings. • Is the "BUSY" indication displayed on the operation panel? When the "BUSY" indication is displayed on the operation panel, a user with higher priority is controlling the camera. Operating Instructions (PDF) • Are signals correctly supplied to the ALARM/CONTROL connector and the ALARM connector at the rear? • Is the ALARM connector configured correctly? 44, 48 48 • Is the alarm operational mode set to "ALM"? Check the settings. • Check if the alarm suspension is activated. Reset the alarm suspension. 72, 73, 74, 75 Operating Instructions (PDF) • Are the cameras connected correctly? 29 Check the camera connection. • When the camera connection is correct, contact your dealer since it may be possible that is caused by the cable discon- - nection or the camera malfunction. • The range of ambient operating temperature is between +5 °C and +45 °C {+41 °F - +113 °F}. However, the "THERMAL" indication will be displayed when the recorder detected the ambient temperature in excess of +40 °C {+104 °F}. When the "THERMAL" indication is displayed, 12 reconsider the installation place to protect the hard disk drives or take measures to keep the ambient temperature between +20 °C - +30 °C {+68 °F - +86 °F}. When the "THERMAL" indication is displayed frequently, contact your dealer. • Is the built-in battery charged enough? Operate the recorder for 48 hours or more to charge the built- 12 in battery. • Is the built-in battery worn out? The built-in battery life is approx. 5 years as an indication of 12 replacement. (The built-in battery life may become shorter depending on the use condition.) • Make sure that the connection cable provided with the extension unit is being used. 33 • Make sure that the connection cable is not loose. 33 149

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

149
Symptom
Check item/Remedy
Ref. Page
Cannot control the camera.
• Is the user level of the current login user allowed to control the
camera?
Check the settings.
108
• Is the "BUSY" indication displayed on the operation panel?
When the "BUSY" indication is displayed on the operation
panel, a user with higher priority is controlling the camera.
Operating
Instructions
(PDF)
Alarm operations are not
activated.
• Are signals correctly supplied to the ALARM/CONTROL con
-
nector and the ALARM connector at the rear?
44, 48
• Is the ALARM connector configured correctly?
48
• Is the alarm operational mode set to "ALM"?
Check the settings.
72, 73, 74, 75
• Check if the alarm suspension is activated.
Reset the alarm suspension.
Operating
Instructions
(PDF)
The "VIDEO LOSS" indica
-
tion is displayed.
• Are the cameras connected correctly?
Check the camera connection.
29
• When the camera connection is correct, contact your dealer
since it may be possible that is caused by the cable discon-
nection or the camera malfunction.
The "THERMAL" indication
is displayed.
• The range of ambient operating temperature is between
+5 °C and +45 °C {+41 °F - +113 °F}. However, the
"THERMAL" indication will be displayed when the recorder
detected the ambient temperature in excess of +40 °C
{+104 °F}. When the "THERMAL" indication is displayed,
reconsider the installation place to protect the hard disk drives
or take measures to keep the ambient temperature between
+20 °C - +30 °C {+68 °F - +86 °F}. When the "THERMAL"
indication is displayed frequently, contact your dealer.
12
The clock loses time.
• Is the built-in battery charged enough?
Operate the recorder for 48 hours or more to charge the built-
in battery.
12
• Is the built-in battery worn out?
The built-in battery life is approx. 5 years as an indication of
replacement. (The built-in battery life may become shorter
depending on the use condition.)
12
The extension unit is not rec
-
ognized (even when con-
necting the extension unit).
• Make sure that the connection cable provided with the exten
-
sion unit is being used.
33
• Make sure that the connection cable is not loose.
33