Panasonic WJ-HD716/1000 Installation Guide - Page 42
Connection of RS485 cameras
View all Panasonic WJ-HD716/1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Connection of RS485 cameras The following are examples when connecting RS485 cameras to the recorder. Up to 8 RS485 cameras can be connected to a single RS485 port. Important: • Select "On" for the termination setting of the devices on both ends of the connection. The termination setting of the recorder can be set using the mode switch. (☞ Page 51) • When connecting RS485 cameras, configure the settings on the [RS485 setup] tab under the "Communication" page of the setup menu together with the RS485 settings of each camera. (☞ Page 94) • The maximum RS485 cable length for this connection is 1 200 m {3 937 ft}. 1-on-1 connection Connect a single RS485 camera to the RS485 port. Example: When connecting RS485 cameras to the video input connector 9 and 13 Mode switch ON 1 2 3 4 5 6 78 (No.1 and No.4: ON) IN OUT EXT STORAGE MODE DATA RS485(CAMERA) 10/100BASE-T 3 2 ALARM ALARM/CONTROL 1 1 MONITOR OUT 2 OUT-CASCADE-IN 12345678 2 2 1 2 1 CASCADE IN OUT MONITOR OUT(HD) 1 3 1 IN CASCADE OUT 4 2 AUDIO AUDIO IN OUT 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 7 1 OUT 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 VIDEO Recorder POWER ON OFF AC IN SIGNAL GND RS485 cable (WV-CA48/50) RS485 camera connection destination Switch to be set 4-wire connection RS485 (1) No.2 and No.3 ON 1 2 3 4 5 6 78 (No.2 and No.3: OFF) 2-wire connection ON 1 2 3 4 5 6 78 (No.2 and No.3: ON) RS485 (2) No.5 and No.6 ON 1 2 3 4 5 6 78 (No.5 and No.6: OFF) ON 1 2 3 4 5 6 78 (No.5 and No.6: ON) Unit number 13 Unit number 9 Termination: On Termination: On Combination camera 42