Brother International Quattro 2 6700D Users Manual - English - Page 341
and then slide it toward you.
View all Brother International Quattro 2 6700D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 341 highlights
a Press the "Needle the needle. Position" button to raise b Turn the main power to OFF. c Remove the needle and the presser holder (see pages 66 through 67). foot d Remove the flat bed attachment or the embroidery unit if either is attached. e Grasp both sides of the needle and then slide it toward you. plate cover, CARE AND MAINTENANCE g Use the cleaning brush to remove any lint and or a vacuum cleaner dust from the race and bobbin thread sensor and the surrounding area. a Cleaning brush b Race c Bobbin thread sensor a Needle plate cover → The needle plate cover is removed. f Grasp the bobbin case, and then pull it out. Note • Do not apply oil to the bobbin case. • If lint or dust collects on the bobbin thread sensor, the sensor may not operate correctly. h Insert the bobbin case so that the S mark on the bobbin case aligns with the z mark on the machine. a a Bobbin case b a b * Align the S and z marks. 9 Appendix a S mark b z mark c Bobbin case 339