Dell Force10 S55T FTOS Command Line Reference Guide for the S55 System FTOS 8. - Page 160
ethernet cfm mep, ethernet cfm mip
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
www.dell.com | support.dell.com Syntax Defaults Command Modes Command History ethernet cfm Disabled CONFIGURATION Version 8.3.5.0 Version 8.3.1.0 Introduced on the S55. Introduced on S-Series ethernet cfm mep s Create an MEP. Syntax ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-name name mepid mep-id Parameters [up-mep | down-mep] domain [name | level] ma-name name mepid mep-id Specify whether the MEP is up or down facing. Up-MEP: monitors the forwarding path internal to an bridge on the customer or provider edge; on Dell Force10 systems the internal forwarding path is effectively the switch fabric and forwarding engine. Down-MEP: monitors the forwarding path external another bridge. Enter this keyword followed by the domain name or domain level. Enter this keyword followed by the name of the maintenance association. Enter an MEP ID. Range: 1-8191 Defaults None Command Modes INTERFACE Command History Version 8.3.5.0 Version 8.3.1.0 Introduced on the S55. Introduced on S-Series ethernet cfm mip s Create an MIP. Syntax Parameters ethernet cfm mip domain {name | level} ma-name name domain [name | level] ma-name name Enter this keyword followed by the domain name or domain level. Enter this keyword followed by the name of the maintenance association. Defaults Command Modes Command History None INTERFACE Version 8.3.5.0 Version 8.3.1.0 Introduced on the S55. Introduced on S-Series 160 | 802.1ag