CONF-1021, Message, Probable Cause, Recommended, Action, Severity, configDefault
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 128 highlights
11 CONF-1021 CONF-1021 Message , [CONF-1021], ,, INFO, , configUpload not permitted . Probable Cause There are many possible causes. Recommended Check the error log for a possible cause. Please correct the error and upload the configuration Action again. Severity INFO CONF-1022 Message , [CONF-1022], ,, INFO, , Downloading configuration without disabling the switch was unsuccessful. Probable Cause Indicates that an attempt to download the configuration without disabling the switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch and try to download configuration again. Action Severity INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable Cause Previous configuration commands have loaded database. Configuration changes associated with specified key have not been applied. Recommended Use configure and other various commands to erase unneeded configuration parameters. As a last Action resort, execute configDefault and re-configure the system. Severity INFO 76 Fabric OS Message Reference 53-1000600-02