Page 494 highlights
70 SWCH-1011 Severity WARNING SWCH-1011 Message , [SWCH-1011], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Trunk Area functionality. (active ver = , Trunk Area enabled on switch = ). Probable Cause Indicates that the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity WARNING 442 Fabric OS Message Reference 53-1000600-02
442
Fabric OS Message Reference
53-1000600-02
SWCH-1011
70
Severity
WARNING
SWCH-1011
Message
<timestamp>, [SWCH-1011], <sequence-number>,, WARNING, <system-name>, HA state
out of sync: Standby CP (ver = <standby SWC version>) does not support Trunk Area
functionality. (active ver = <active SWC version>, Trunk Area enabled on switch =
<'1' if Trunk Area ports exist; Otherwise '0'>).
Probable Cause
Indicates that the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.
Recommended
Action
Load a firmware version on standby that supports Trunk Area functionality, using the
firmwareDownload
command.
Severity
WARNING