6) Move the lamp unit by hand and check that it move smoothly in all movable area. NOTE: Check that there is no interference of the harness of the scanner heater in the wire and the 2/3 mirror unit. F. Operation check after installation 1) Turn on the dehumidifier heater switch. (4) Installation of the table glass, the paper exit cover 1) Install the paper exit cover. 2) Measure the resistance value between the earth terminal and the AC terminal (L side), and between the earth terminal and AC terminal (N side) with the circuit tester, and confirm they are not short-circuited. 2) Install the table glass. Install the SPF glass and the glass holder, and secure it with the screw. 3) When not using the heater after checking, turn off the dehumidifier heater switch. MX-M503N Dehumidifying heater 27 - 6