Sharp MX-M363N Installation Manual - Page 111
Check C., front side of then RSPF bottom is in contact with the glass
View all Sharp MX-M363N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
1 : '10/Jun/18 1 Check section B. Is there a re- No sistance? Yes d) Check section B. Place the RSPF height adjustment sheet between section B and the RSPF glass height adjustment resin surface (a), and close the RSPF unit. Slowly pull out the RSPF height adjustment sheet. Check to insure that a slight resistance is felt when pulling out the RSPF height adjustment sheet. (If the boss in section B is in contact, it is O.K.) * Be careful not to put the book sensor (b) on the height adjustment sheet. B b a e) If it can be pulled out without resistance, turn the hinge in section E clockwise to adjust. E Check section C. Is there No a separating section. Yes Adjust hinge E until the separation in section C is deleted. (Counterclockwise) * The bosses in section A and B are excessively pressed. (The right side is separating.) End of the adjustment f) Check section C. Check to confirm that the projection in section C in the right front side of then RSPF bottom is in contact with the glass surface (b). b C C b MX-M503N MX-RP11 28 - 5