Error Code, Description, User Action, Table 8-1. Main Error Codes continued

Page 185 highlights

Table 8-1. Main Error Codes (continued) Error Code Description 8E Cannot find gripper block within the expected range 8F Cannot find slider block within the expected range 90 Cannot find elevator block within the expected range 91 Cannot find rotation block within the expected range 92 Cannot find sled block within the expected range 93 Gripper outside range, User Action Gripper has reached a position beyond the expected range 94 Slider outside range, Slider has reached a position beyond the expected range 95 Elevator outside range, Elevator has reached a position beyond the expected range 96 Rotation outside range, Refer to "Isolating a Library Controller Card vs. Accessor Rotation has reached a position beyond Enclosure Problem" on page 7-10. Possible Replacement the expected range CRUs: 97 Sled outside range, v Primary: Library Enclosure v Secondary: Library Controller Card Sled has reached a position beyond the expected range 98 Cartridge present sensor not found 99 Slider home sensor not found 9A Rotation home sensor not found 9B Sled position sensor (fiducial sensor) not found 9C Gripper range out of specification 9D Slider range out of specification 9E Elevator range out of specification 9F Rotation range out of specification A0 Sled range out of specification A1 Open I/O Station (Import/Export Element) failed B0 Robotic controller response timeout. A command did not complete in the required amount of time. B1 NACK (not acknowledged) received from robotic controller B2 Accessor controller communication failed Chapter 8. Error Codes 8-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283

Table 8-1. Main Error Codes (continued)
Error Code
Description
User Action
8E
Cannot find gripper block within the
expected range
Refer to “Isolating a Library Controller Card vs. Accessor
Enclosure Problem” on page 7-10. Possible Replacement
CRUs:
v
Primary: Library Enclosure
v
Secondary: Library Controller Card
8F
Cannot find slider block within the
expected range
90
Cannot find elevator block within the
expected range
91
Cannot find rotation block within the
expected range
92
Cannot find sled block within the
expected range
93
Gripper outside range,
Gripper has reached a position beyond
the expected range
94
Slider outside range,
Slider has reached a position beyond the
expected range
95
Elevator outside range,
Elevator has reached a position beyond
the expected range
96
Rotation outside range,
Rotation has reached a position beyond
the expected range
97
Sled outside range,
Sled has reached a position beyond the
expected range
98
Cartridge present sensor not found
99
Slider home sensor not found
9A
Rotation home sensor not found
9B
Sled position sensor (fiducial sensor) not
found
9C
Gripper range out of specification
9D
Slider range out of specification
9E
Elevator range out of specification
9F
Rotation range out of specification
A0
Sled range out of specification
A1
Open I/O Station (Import/Export
Element) failed
B0
Robotic controller response timeout. A
command did not complete in the
required amount of time.
B1
NACK (not acknowledged) received
from robotic controller
B2
Accessor controller communication failed
Chapter 8. Error Codes
8-3