HP NetServer AA 4000 HP Netserver AA Solution Administrator's Guide v - Page 150

Table 5-25, IOP LinkDriver Port Counters, Continued

Page 150 highlights

Table 5-25 IOP LinkDriver Port Counters (Continued) Value Meaning Receives Out of Sequence Data PDUs Received Acks Received Control PDUs Received Circuit ID Mismatch Errors Invalid Ethernet Packets Received Acks Received with Initial Transmit Pending Acks Received with Retransmit Pending Retransmit Timeouts with Transmit Pending NDIS Packets Unavailable for Send NDIS Buffers Unavailable for Send NDIS Packets Unavailable for Receive NdisSend Errors NdisTransferData Errors NdisTransferData Incomplete Number of Data PDUs received out of sequence. The sequence number received did not agree with the sequence number that was expected. Number of Data PDUs received Number of ACK PDUs received Number of Control PDUs received Number of times we received a control PDU with the wrong circuit ID Number of invalid Ethernet packets received An ACK was received for a data PDU for which the initial transmit is pending. An ACK was received for a data PDU for which a retransmit is pending. The retransmit timer expired, but the data PDU is still pending from a previous transmit. Number of times an NDIS_PACKET in which to send a PDU could not be allocated Number of times an NDIS_BUFFER in which to send a PDU could not be allocated Number of times an NDIS_PACKET in which to copy a PDU received by the Ethernet driver could not be allocated Number of errors returned by NdisSend Number of errors returned by NdisTransferData Number of times NdisTransferData did not copy the requested number of bytes See Also IOPn.LinkDriver Reset Port Counters 5-62 HP Netserver AA Solution Administrator's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272

5-62
HP Netserver AA Solution Administrator°s Guide
See Also
IOPn.LinkDriver Reset Port Counters
Receives Out of Sequence
Number of Data PDUs received out of sequence. The
sequence number received did not agree with the
sequence number that was expected.
Data PDUs Received
Number of Data PDUs received
Acks Received
Number of ACK PDUs received
Control PDUs Received
Number of Control PDUs received
Circuit ID Mismatch Errors
Number of times we received a control PDU with the
wrong circuit ID
Invalid Ethernet Packets Received
Number of invalid Ethernet packets received
Acks Received with Initial Transmit Pending
An ACK was received for a data PDU for which the initial
transmit is pending.
Acks Received with Retransmit Pending
An ACK was received for a data PDU for which a
retransmit is pending.
Retransmit Timeouts with Transmit Pending
The retransmit timer expired, but the data PDU is still
pending from a previous transmit.
NDIS Packets Unavailable for Send
Number of times an NDIS_PACKET in which to send a
PDU could not be allocated
NDIS Buffers Unavailable for Send
Number of times an NDIS_BUFFER in which to send a
PDU could not be allocated
NDIS Packets Unavailable for Receive
Number of times an NDIS_PACKET in which to copy a
PDU received by the Ethernet driver could not be
allocated
NdisSend Errors
Number of errors returned by NdisSend
NdisTransferData Errors
Number of errors returned by NdisTransferData
NdisTransferData Incomplete
Number of times NdisTransferData did not copy the
requested number of bytes
Table 5-25
IOP LinkDriver Port Counters
(Continued)
Value
Meaning