HP NetServer AA 4000 HP Netserver AA Solution Administrator's Guide v - Page 246

Reset, Endurance Sector, If any of the above steps do not perform as documented, contact your service

Page 246 highlights

Step Action Notes 5 Initialize the Endurance sector on the replacement disk: • From the application task bar, select Start Programs Marathon Endurance Endurance Manager. • From the Endurance Manager, issue the command IOPn.Diskx Reset Endurance Sector. • Substitute for n the number of the IOP in which the replacement disk was installed. • Substitute for x the number of the CE disk of the mirror set in which it was a member. For example: IOP2.Disk1 Reset Endurance Sector 6 If the local IOP is not enabled, enable Verify that the IOPs are joined and both are online it now: (bright green on the Endurance Manager display). • From the application task bar, select Start Programs Marathon Endurance Endurance Manager. • From the Endurance Manager, issue the command IOPn Enable Operation From IOP1. 7 Verify that all mirror sets are Current, Using Endurance Manager, in the Last Mirror Copy Started, or Pending. Status WIndow, determine the status of all mirror copies that may be required. Refer to Chapter 4 for The destination IOP is the local IOP detailed information about how to run and use the in which the replacement drive was Endurance Manager. installed. 8 Verify that all mirror copies complete. Refer to Chapter 4 for detailed information about how to run and use the Endurance Manager. Note: If any of the above steps do not perform as documented, contact your service provider for assistance. 9-30 HP Netserver AA Solution Administrator's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272

9-30
HP Netserver AA Solution Administrator°s Guide
Note:
If any of the above steps do not perform as documented, contact your service
provider for assistance.
5
Initialize the Endurance sector on the
replacement disk:
°
From the application task bar,
select
Start
Programs
Marathon
Endurance
Endurance Manager
.
°
From the Endurance Manager,
issue the command
IOP
n
.Disk
x
Reset
Endurance Sector
.
°
Substitute for
n
the number of the IOP in which
the replacement disk was installed.
°
Substitute for
x
the number of the CE disk of the
mirror set in which it was a member. For example:
IOP2.Disk1 Reset Endurance Sector
6
If the local IOP is not enabled, enable
it now:
°
From the application task bar,
select
Start
Programs
Marathon
Endurance
Endurance Manager
.
°
From the Endurance Manager,
issue the command
IOPn
Enable Operation From
IOP1
.
Verify that the IOPs are joined and both are
online
(bright green on the Endurance Manager display).
7
Verify that all mirror sets are
Current
,
Started
, or
Pending
.
The destination IOP is the local IOP
in which the replacement drive was
installed.
Using Endurance Manager, in the Last Mirror Copy
Status WIndow, determine the status of all mirror
copies that may be required.
Refer to
Chapter 4
for
detailed information about how to run and use the
Endurance Manager.
8
Verify that all mirror copies complete.
Refer to
Chapter 4
for detailed information about
how to run and use the Endurance Manager.
Step
Action
Notes