Lexmark C540 Service Manual - Page 54

xx, 4xx, CRC Failure, Error Correction Code ECC, Failure, Service error messages 1xx, 9xx continued

Page 54 highlights

5025-2xx, 4xx Service error messages (1xx, 9xx) (continued) Error code 950.xx Service NVRAM Failure 951.xx Service NVRAM Failure 952.xx Service NVRAM Failure:n 953.xx Service NVRAM Failure 954.xx Service NVRAM Failure 955.xx Service Code CRC 956.00 Service System Board 956.01 Service System Board Description Action There is a mismatch between controller EEPROM and mirror. • 950.00 through 950.29 codes: mismatch between controller and mirror • 950.30 through 950.60 codes: mismatch between secure and controller Go to "950.xx NVRAM Failure service check" on page 2-26. Mismatch between controller EEPROM and mirror. • 951.00 through 951.29 codes: mismatch between controller and mirror • 951.30 through 951.60: mismatch between secure and controller A recoverable MVRAM Cyclic Redundancy Check (CRC) error occurred. n is the offset at which the error occurred. Performing a POR will clear this error. NVRAM chip failure with mirror. The NVRAM chip failure with controller part. The Code ROM or NAND flash failed the Cyclic Redundancy Check (CRC) check or the NAND experienced an uncorrectable multi-bit failure. indicates the source of the failure and has one of the following values: • CRC Failure: The source is a failing package indicated by Pn where n is the package number. This error could occur on a controller with ROM or NAND flash and could occur as a result of the CRC check done when the machine is powered on. The range of package numbers is from 0 to 15. • Error Correction Code (ECC) Failure: The source is a failing page indicated by Bn where "n" is the page number. This error occurs only if a multi-bit failure is detected during the ECC execution. Single bit failures will be corrected automatically and will not result in a service error. The range of page numbers is from 0 to 1023. Controller board failure. Processor failure. Replace the controller board. See "Controller board removal" on page 4-19. Processor over temperature. Replace the controller board. See "Controller board removal" on page 4-19. 2-20 Service Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236

2-20
Service Manual
5025-2xx, 4xx
950.
xx
Service
NVRAM Failure
There is a mismatch between controller
EEPROM and mirror.
950.00 through 950.29 codes:
mismatch between controller and
mirror
950.30 through 950.60 codes:
mismatch between secure and
controller
Go to
“950.xx NVRAM Failure service
check” on page 2-26
.
951.
xx
Service
NVRAM Failure
Mismatch between controller EEPROM
and mirror.
951.00 through 951.29 codes:
mismatch between controller and
mirror
951.30 through 951.60: mismatch
between secure and controller
952.
xx
Service
NVRAM Failure:
n
A recoverable MVRAM Cyclic
Redundancy Check (CRC) error
occurred.
n
is the offset at which the
error occurred.
Performing a POR will clear this error.
953.
xx
Service
NVRAM Failure
NVRAM chip failure with mirror.
954.
xx
Service
NVRAM Failure
The NVRAM chip failure with controller
part.
955.
xx
Service
Code CRC <
loc
>
The Code ROM or NAND flash failed
the Cyclic Redundancy Check (CRC)
check or the NAND experienced an
uncorrectable multi-bit failure. <
loc
>
indicates the source of the failure and
has one of the following values:
CRC Failure
: The source is a
failing package indicated by P
n
where
n
is the package number.
This error could occur on a
controller with ROM or NAND flash
and could occur as a result of the
CRC check done when the
machine is powered on. The range
of package numbers is from 0 to
15.
Error Correction Code (ECC)
Failure
: The source is a failing
page indicated by B
n
where “
n
” is
the page number. This error occurs
only if a multi-bit failure is detected
during the ECC execution. Single
bit failures will be corrected
automatically and will not result in a
service error. The range of page
numbers is from 0 to 1023.
956.00 Service
System Board
Controller board failure. Processor
failure.
Replace the controller board. See
“Controller board removal” on
page 4-19
.
956.01 Service
System Board
Processor over temperature.
Replace the controller board. See
“Controller board removal” on
page 4-19
.
Service error messages (1xx, 9xx) (continued)
Error code
Description
Action