E122D Memory, E1243 CPU # VCORE
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Code Text Causes Corrective Actions E122D Memory One of the memory voltage Regulator # regulators failed. Failed. Reseat DIMMs. Reseat the memory modules. See "Troubleshooting System Memory" on page 159. E122E On-board regulator failed. Call support. One of the on-board voltage Remove AC power to the regulators failed. system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. E1243 CPU # VCORE Regulator failure. Contact Support. Processor voltage regulator failed. Reseat the processor. See "Troubleshooting the Processors" on page 168. If the problem persists, see "Getting Help" on page 185. E1310 Fan ## RPM exceeding range. Check fan. RPM of specified fan is outside the intended operating range. See "Troubleshooting System Cooling Problems" on page 157. E1313 Fan redundancy lost. Check fans. The system is no longer fan Check LCD for additional redundant. Another fan scrolling messages. See failure would put the system "Troubleshooting a Fan" at risk of over-heating. on page 158. E1314 Critical system cooling loss. Check fans. All fans have been removed from the system. Ensure that the fans are properly installed. See "Troubleshooting a Fan" on page 158. E1410 System Fatal A fatal system error Error detected. detected. Check LCD for additional scrolling messages. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. About Your System 25