Dell PowerEdge R815 Hardware Owner's Manual - Page 49
The DIMM group for CPU, Warning! Power - cpu upgrades
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Message Causes Corrective Actions Warning! Power required exceeds PSU wattage. Check PSU and system configuration. Warning! Performance degraded. CPU and memory set to minimum frequencies to meet PSU wattage. System will reboot. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High Output power supplies to use the components. See "Power Supplies" on page 85. Write fault Write fault on selected drive. Faulty USB device, USB Replace the USB medium or medium, optical drive device. Ensure that the USB, assembly, hard drive, or hard- SAS backplane, or SATA drive subsystem. cables are properly connected. See "Troubleshooting a USB Device" on page 152, "Troubleshooting an Internal USB Key" on page 161, and "Troubleshooting a Hard Drive" on page 164. Incorrect memory configuration CPU n. The DIMM group for CPU n See "General Memory is incorrectly configured and Module Installation caused the system to halt. Guidelines" on page 93, for memory configuration information. If the problem persists, see "Troubleshooting System Memory" on page 159. About Your System 49